Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Inhalation: IF INHALED. Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor/.../if you feel unwell.

Skin: Wash with plenty of soap and water. Take off contaminated clothing and wash before re-use. Eyes

Flush eyes with plenty of water. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists, get medical advice/attention.

Ingestion: If a large amount is swallowed, get medical attention.

Most Important Symptoms/Effects

Acute: May cause respiratory irritation.

Delayed: No information on significant adverse effects.

Fire-fighting measures

Extinguishing media

Suitable extinguishing media: Water spray, carbon dioxide, regular dry chemical.

Unsuitable Extinguishing Media: None known.

Special hazards arising from the substance or mixture:

Open and handle container with care. Do not cut, puncture, or weld on or near this container. Grounding and bonding required.

Combustion: oxides of carbon.

Advice for firefighters:

Eliminate all sources of ignition. Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Cool containers with water from unmanned hose holder or monitor nozzles until well after fire is out.

Fire Fighting Measures:

Avoid inhalation of material or combustion by-products. Move material from fire area if it can be done without risk. Use extinguishing agents appropriate for surrounding fire. Dike for later disposal. Stay upwind and keep out of low areas.

Protective Equipment and Precautions for Firefighters:

Wear full protective fire fighting gear including self contained breathing apparatus (SCBA) for protection against possible exposure.

Accidental release measures

Personal precautions, protective equipment and emergency procedures: Wear appropriate chemical resistant clothing. Wear appropriate chemical resistant gloves.

Environmental precautions: Do not allow to enter into surface water or drains.

Methods and Materials for Containment and Cleaning Up:

Ensure waste is collected and contained. Eliminate all sources of ignition. Ventilate the area. Keep unnecessary people away, isolate hazard area and deny entry. Collect spilled material in appropriate container for disposal. Clean up residue with a high-efficiency particulate filter vacuum.

Handling and storage

Precautions for safe handling

Avoid contact with skin, eyes and clothes. Avoid prolonged or repeated contact with skin or eyes. Wash thoroughly after handling. Wash with plenty of soap and water. Avoid breathing dust. Use this material with adequate ventilation.

Conditions for safe storage, including any incompatibilities:

Store in a well-ventilated place. Keep cool. Store below 40 C. Keep container tightly closed. Keep container upright, when not in use, to prevent leakage. Avoid contact with incompatible materials. Store locked up.

Incompatible Materials: strong bases

Specific end use(s): Intermediate.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Component Exposure Limits:EU, Austria, Belgium, Denmark, Finland, France, Germany, Greece, Ireland, Netherlands, Portugal, Spain, Sweden and United Kingdom have not developed exposure limits for any of this product's components.

Biological limit value: There are no biological limit values for any of this product's components.

Derived No Effect Levels (DNELs): No DNELs available

Predicted No Effect Concentrations (PNECs): No PNECs available.

Exposure Controls

Engineering controls: Provide local exhaust or process enclosure ventilation system. Ensure adequate ventilation. Ensure compliance with applicable exposure limits.

Eye/face protection: Safety glasses or goggles are recommended when there is a potential for eye contact.

Skin Protection: Wear appropriate chemical resistant clothing.

Respiratory Protection: In case of inadequate ventilation wear respiratory protection.

Glove Recommendations: Wear protective gloves.

Protective Materials: Provide an emergency eye wash fountain and quick drench shower in the immediate work area.

Environmental exposure controls: Avoid release to the environment.

Stability and reactivity

Reactivity: No hazard expected.

Chemical stability: Stable under normal conditions of use.

Possibility of hazardous reactions: No hazard expected.

Conditions to avoid: Avoid contact with incompatible materials.

Incompatible materials: strong bases

Hazardous decomposition products: oxides of carbon

Disposal considerations

Dispose of contents/container in accordance with local/regional/national/international regulations.