First-aid measures

Emergency measure - Inhalation: Remove person to fresh air. Symptomatic treatment. Seek

medical attention.

Emergency measure - Eyes: Flush eyes continuously with water for at least 15 minutes.

If irritation persists seek medical advice.

Emergency measure - Skin: Wash affected area thoroughly with soap and plenty of water.

If irritation persists seek medical advice. Launder clothing

before reuse.

Emergency measure - Ingestion: Seek medical advice.

Fire-fighting measures

Recommended extinguishing agent: dry powder, foam, carbon dioxide, water spray

Product arising from burning: The substance is combustible and will burn if involved in a

fire, evolving noxious fumes (eg oxides of carbon).

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing

apparatus must be worn.

Fight the fire from a safe distance or protected location.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.

Wear appropriate personal protective equipment conforming to

the relevant national or international standards, as

mentioned in section 2.3.10.

Avoid dust formation. Absorb spillages of solutions with a

suitable inert material (eg. sand or soil). Carefully

transfer the spillage to waste containers, or use a sealed

industrial vacuum machine. Containers filled with waste

material must be labelled in the same way as the original

substance containers.

Clean the spillage area with detergent and water.

Dispose of waste material in accordance with local

regulations by incineration.

Handling and storage

Handling: The substance should be stored, handled and used under

conditions of good industrial hygiene and in conformity with

any local regulations in order to avoid exposure.

Engineering controls are necessary to reduce exposure to the

substance.

When exposure cannot be prevented or adequately controlled

appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate

international or national standards as follows;

Chemical protective gloves to Standard prEN374

Chemical protective clothing to Standard EN368

Eye protection to Standard prEN166.

Furthermore, when respiratory protective equipment has to be

used, it must be capable of adequately controlling exposure,

be suitable for the purpose, and conform to the appropriate

international or national standards, such as a dust mask

conforming to EN149 FFP1.

Storage: Store in a cool, dry, well-ventilated area, away from

sources of ignition.

Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: 55 gallon drums

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: None
Transport: Avoid crushing the containers. In the event of a spillage,
observe the warning labels on the container.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

When exposure cannot be prevented or adequately controlled

appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate

international or national standards as follows;

Chemical protective gloves to Standard prEN374

Chemical protective clothing to Standard EN368

Eye protection to Standard prEN166.

Furthermore, when respiratory protective equipment has to be

used, it must be capable of adequately controlling exposure,

be suitable for the purpose, and conform to the appropriate

international or national standards, such as a dust mask

conforming to EN149 FFP1.

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None

Dust explosion: There is a potential dust explosion hazard form this organic

powder.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Discharge to the environment will be minimal. Recovery from

minor spillages or accidental discharge is not economically

or technically feasible, and such waste material will be

disposed of by incineration or landfill. In principle, it

may be possible to recover larger spillages of

uncontaminated material for subsequent use.

Industry - Possibility of neutralisation: The notification tests have shown that the substance is not

hazardous so chemical treatment is not necessary.

The potential dust dust hazard will be controlled by

appropriate storage and handling techniques.

Industry - Possibility of destruction: controlled discharge: Contaminated containers or spillages of solutions mixed with

inert material (eg. sand or soil) may be disposed of by

landfill at an authorised tip in accordance with local

regulations.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning

under controlled conditions at a licensed waste treatment

processor in accordance with local regulations. Stack gases

should be scrubbed, because noxious fumes (eg. oxides of

carbon) could be formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly to

the sewage system or the aqueous environment. However,

adverse effects  on sewage treatment systems would be

unlikely as the substance has been shown not to be toxic to

sewage mico-organisms.

Public at large - Possibility of recovery/recycling: Not applicable as the substance will not enter the public

domain.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.