This list contains the application exemptions listed in Annexes III and IV to RoHS (2011/65/EU). Annex III contains applications exempted from the restriction in Article 4(1), while Annex IV lists applications exempted from the restriction in Article 4(1) specific to medical devices and monitoring and control instruments.

Last updated 16 aprile 2021. Database contains 122724 unique substances/entries.
Filter the list

 
204-211-0
117-81-7
III
43
In rubber components in engine systems, designed for use in equipment that is not intended solely for consumer use and provided that no plasticised material comes into contact with human mucous membranes or into prolonged contact with human skin and the concentration value of bis(2-ethylhexyl) phthalate does not exceed: (a) 30 % by weight of the rubber for (i) gasket coatings, (ii) solid-rubber gaskets, or (iii) rubber components included in assemblies of at least three components using electrical, mechanical or hydraulic energy to do work, and attached to the engine. (b) 10 % by weight of the rubber for rubber-containing components not referred to in point (a)
07/21/2024
Details
-
-
III
30
As electrical/mechanical solder joints to electrical conductors located directly on the voice coil in transducers used in high-powered loudspeakers with sound pressure levels of 100 dB (A) and more
Details
-
-
III
8(b)
In electrical contacts
Details
-
-
III
8(a)
In one shot pellet type thermal cut-offs
01/01/2012
Details
-
-
IV
44
In radiation tolerant video camera tubes designed for cameras with a centre resolution greater than 450 TV lines which are used in environments with ionising radiation exposure exceeding 100 Gy/hour and a total dose in excess of 100kGy
03/31/2027
Details
-
-
IV
43
Anodes in Hersch cells for oxygen sensors used in industrial monitoring and control instruments, where sensitivity below 10 ppm is required
07/15/2023
Details
-
-
III
40
In photoresistors for analogue optocouplers applied in professional audio equipment
12/31/2013
Details
-
-
III
38
In thick film pastes used on aluminium bonded beryllium oxide
Details
-
-
III
21
In printing inks for the application of enamels on glasses, such as borosilicate and soda lime glasses
Details
-
-
III
13(b)-(III)
In glazes used for reflectance standards
07/21/2021
Details
-
-
III
13(b)-(II)
In striking optical filter glass types, excluding applications falling under point 39 of Annex III
07/21/2021
Details
-
-
III
13(b)
In filter glasses and glasses used for reflectance standards
07/21/2021
Details
-
-
III
13(b)
In filter glasses and glasses used for reflectance standards
07/21/2024
Details
-
-
III
13(b)
In filter glasses and glasses used for reflectance standards
07/21/2023
Details
-
-
IV
21
In spare parts for X-ray systems placed on the EU market
01/01/2020
Details
-
-
IV
31a(c)
In spare parts recovered from and used for the repair or refurbishment of medical devices, including in vitro diagnostic medical devices, or electron microscopes and their accessories, provided that the reuse takes place in auditable closed-loop business-to-business return systems and that each reuse of parts is notified to the customer
07/21/2024
Details
-
-
IV
31a(b)
In spare parts recovered from and used for the repair or refurbishment of medical devices, including in vitro diagnostic medical devices, or electron microscopes and their accessories, provided that the reuse takes place in auditable closed-loop business-to-business return systems and that each reuse of parts is notified to the customer
07/21/2023
Details
-
-
IV
31a(a)
In spare parts recovered from and used for the repair or refurbishment of medical devices, including in vitro diagnostic medical devices, or electron microscopes and their accessories, provided that the reuse takes place in auditable closed-loop business-to-business return systems and that each reuse of parts is notified to the customer
07/21/2021
Details
-
-
IV
21
In phosphor coatings in image intensifiers for X-ray images
12/31/2019
Details
-
-
IV
20
In X-ray measurement filters
Details
-
-
IV
12
In metallic bonds creating superconducting magnetic circuits in MRI, SQUID, NMR (Nuclear Magnetic Resonance) or FTMS (Fourier Transform Mass Spectrometer) detectors
06/30/2021
Details
-
-
IV
10
In atomic absorption spectroscopy lamps
Details
-
-
IV
9
In helium-cadmium lasers
Details
-
-
IV
1c
Sensors, detectors and electrodes: In infra-red light detectors
Details
-
-
IV
1a
Sensors, detectors and electrodes: In ion selective electrodes including glass of pH electrodes
Details
-
-
IV
1
Equipment utilising or detecting ionising radiation: In detectors for ionising radiation
Details
215-146-2
1306-19-0
III
38
In thick film pastes used on aluminium bonded beryllium oxide
Details
215-148-3
1306-24-7
III
39(a)
In downshifting cadmium-based semiconductor nanocrystal quantum dots for use in display lighting applications
10/31/2019
Details
-
-
III
9
Anticorrosion agent in the cooling solution of the carbon steel cooling system in absorption refrigerators
07/21/2024
Details
-
-
IV
31a(b)
In spare parts recovered from and used for the repair or refurbishment of medical devices, including in vitro diagnostic medical devices, or electron microscopes and their accessories, provided that the reuse takes place in auditable closed-loop business-to-business return systems and that each reuse of parts is notified to the customer
07/21/2023
Details
-
-
IV
31a(c)
In spare parts recovered from and used for the repair or refurbishment of medical devices, including in vitro diagnostic medical devices, or electron microscopes and their accessories, provided that the reuse takes place in auditable closed-loop business-to-business return systems and that each reuse of parts is notified to the customer
07/21/2024
Details
-
-
IV
31a(a)
In spare parts recovered from and used for the repair or refurbishment of medical devices, including in vitro diagnostic medical devices, or electron microscopes and their accessories, provided that the reuse takes place in auditable closed-loop business-to-business return systems and that each reuse of parts is notified to the customer
07/21/2021
Details
-
-
IV
30
In spare parts for X-ray systems placed on the EU market
01/01/2020
Details
-
-
IV
30
In alkali dispensers used to create photocathodes in X-ray image intensifiers
12/31/2019
Details
-
-
III
9
Anticorrosion agent in the cooling solution of the carbon steel cooling system in absorption refrigerators
07/21/2021
Details
-
-
III
9
Anticorrosion agent in the cooling solution of the carbon steel cooling system in absorption refrigerators
07/21/2023
Details
-
-
III
9(a)-II
Anticorrosion agent in the cooling solution of the carbon steel cooling system in absorption refrigerators: - designed to operate fully or partly with electrical heater, having an average utilised power input ≥ 75 W at constant running conditions, - designed to fully operate with non-electrical heater
07/21/2021
Details
-
-
III
9(a)-I
Anticorrosion agent in the cooling solution of the carbon steel cooling system in absorption refrigerators (including minibars) designed to operate fully or partly with electrical heater, having an average utilised power input < 75 W at constant running conditions
03/05/2021
Details
206-104-4
301-04-2
IV
22
Marker for use in stereotactic head frames for use with CT and MRI and in positioning systems for gamma beam and particle therapy equipment
06/30/2021
Details
-
-
III
27
As solder for transducers used in high-powered (designated to operate for several hours at acoustic power levels of 125 dB SPL and above) loudspeakers
09/24/2010
Details
-
-
III
7(c)-I
Electrical and electronic components containing lead in a glass or ceramic other than dielectric ceramic in capacitors, e.g. piezoelectronic devices, or in a glass or ceramic matrix compound
07/21/2021
Details
-
-
III
42
In bearings and bushes of diesel or gaseous fuel powered internal combustion engines applied in non-road professional use equipment: with engine total displacement ≥ 15 litres, or with engine total displacement < 15 litres and the engine is designed to operate in applications where the time between signal to start and full load is required to be less than 10 seconds, or regular maintenance is typically performed in a harsh and dirty outdoor environment, such as mining, construction, and agriculture applications
07/21/2024
Details
-
-
III
44
In solder of sensors, actuators, and engine control units of combustion engines, installed in equipment used at fixed positions while in operation which is designed for professionals, but also used by non-professional users
07/21/2024
Details
-
-
III
37
In the plating layer of high voltage diodes on the basis of a zinc borate glass body
Details
-
-
III
41
In solders and termination finishes of electrical and electronic components and finishes of printed circuit boards used in ignition modules and other electrical and electronic engine control systems, which for technical reasons must be mounted directly on or in the crankcase or cylinder of hand-held combustion engines (classes SH:1, SH:2, SH:3 of Directive 97/68/EC of the European Parliament and of the Council)
03/31/2022
Details
-
-
IV
3
Equipment utilising or detecting ionising radiation: In electromagnetic radiation amplification devices: micro-channel plate and capillary plate
Details
-
-
IV
4
Equipment utilising or detecting ionising radiation: In glass frit of X-ray tubes and image intensifiers and lead in glass frit binder for assembly of gas lasers and for vacuum tubes that convert electromagnetic radiation into electrons
Details
-
-
IV
1
Equipment utilising or detecting ionising radiation: In detectors for ionising radiation
Details
-
-
IV
2
Equipment utilising or detecting ionising radiation: Bearings in X-ray tubes
Details
-
-
IV
1a
Sensors, detectors and electrodes: In ion selective electrodes including glass of pH electrodes
Details

Export search results to: