Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Qualifier:
no guideline followed
Principles of method if other than guideline:
The viscosity has been measured with a viscometer at 20, 40 and 50°C.
The viscosity values are registered in a table.
GLP compliance:
not specified
Type of method:
other: Viscometer
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.757
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.691
Temp.:
other: 50.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.551
Conclusions:
Viscosity at 20°C (room temperature) : 0.757 mm2/sec

Description of key information

Key value for chemical safety assessment

Viscosity:
0.757 mm²/s (static)
at the temperature of:
20 °C