Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 24 May 1993 to 22 February 1994
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1994
Report date:
1994

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
Deviations:
not specified
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
Atrazine
EC Number:
217-617-8
EC Name:
Atrazine
Cas Number:
1912-24-9
Molecular formula:
C8H14ClN5
IUPAC Name:
6-chloro-N2-ethyl-N4-(propan-2-yl)-1,3,5-triazine-2,4-diamine
Details on test material:
Atrazine (technical)
Batch n. 2653, Ref 743
Purity: 97.5%
Expiry: stable until at least January 1995
Appaerance: white powder
Storage conditions: in the dark at 4°C

Study design

Contact with:
powdered cellulose

Results and discussion

Test results (Oxidising solids)open allclose all
Sample tested:
test mixture (not specified)
Remarks:
migrated information
Parameter:
maximum burning rate
Remarks on result:
other: result not specified (migrated information)
Remarks:
None of the test substance/cellulose mixtures burnt for the full 200 mm.
Sample tested:
reference mixture (not specified)
Remarks:
migrated information
Parameter:
maximum burning rate
Result:
2.22 other: mm/s (migrated information)
Remarks on result:
other: the mixture contained 60% of barium nitrate

Any other information on results incl. tables

Burning rate for barium nitrate/cellulose mixtures:

Barium nitrate %

Burning time over 200 mm

Burning rate (mm/s)

Observations

10.2

280

0.71

Burnt across the surface with an orange flame and occasional sparking

19.8

289

0.69

Burnt across the surface with a yellow/orange flame. Low level sparking, a little white ash left.

29.9

256

0.78

Burnt across the surface with a yellow/orange flame. Low level sparking, a little white ash left.

39.9

150

1.33

Burnt across the surface with a yellow/orange flame. Low level sparking, a little white ash left.

50.0

103

1.94

Burnt through the pile with a yellow/orange flame, continuous sparking, 50% white ash left.

59.9

90

2.22

Burnt through the pile with a yellow/orange flame, lots of sparking and some white smoke, white ash and some fused material left.

69.9

137

1.46

Burnt through the pile with a yellow flame, lots of sparking and white smoke, trail of fused material left.

80.1

-

-

Burnt for 10 mm with an almost white flame.

90.0

-

-

Burnt around the igniter with a small white flame.

Burning rate for test substance/cellulose mixtures:

Test substance %

Burning time over 200 mm

Burning rate (mm/s)

Observations

10

-

-

Burnt across the surface with a blue orange tinted flame for 180 mm, a little smoke emitted.

20

-

-

Burnt across the surface with a blue orange tinted flame for 160 mm, a little smoke emitted.

30.2

-

-

Burnt across the surface with a blue orange tinted flame for 30 mm, a little smoke emitted.

40.2

-

-

Burnt across the surface with a blue orange tinted flame for 10 mm, a little smoke emitted.

50.0

-

-

Burnt only around the ignitor with a blue flame.

60

-

-

Burnt only around the ignitor with a blue flame.

69.5

-

-

Burnt only around the ignitor with a blue flame.

79.7

-

-

Burnt only around the ignitor with a blue flame.

89.6

-

-

Burnt only around the ignitor with a blue flame.

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
Under the conditions of this test atrazine (technical) is not considered to have oxidising properties.