Diss Factsheets

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13 November 1987 to 17 November 1987
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1987
Report date:
1987

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
not specified
GLP compliance:
yes
Type of method:
flask method

Test material

Constituent 1
Chemical structure
Reference substance name:
Propazine
EC Number:
205-359-9
EC Name:
Propazine
Cas Number:
139-40-2
Molecular formula:
C9H16ClN5
IUPAC Name:
6-chloro-N2,N4-bis(propan-2-yl)-1,3,5-triazine-2,4-diamine
Details on test material:
Product designation: Propazine
Batch: AMS 129/103
Purified substance

Results and discussion

Water solubility
Water solubility:
0.003 g/L
Temp.:
20 °C
pH:
6.7
Details on results:
The result is the mean of 3 determinations.
The standard deviation of the result is ca 0.0003

Applicant's summary and conclusion

Conclusions:
Interpretation of results (migrated information): slightly soluble (0.1-100 mg/L)