ROHS - Exemptions from Article 4(1) Restrictions, Annexes III & IV

This list contains the application exemptions listed in Annexes III and IV to RoHS (2011/65/EU). Annex III contains applications exempted from the restriction in Article 4(1), while Annex IV lists applications exempted from the restriction in Article 4(1) specific to medical devices and monitoring and control instruments.

Lead and lead compounds

ecnumber: - casnumber: -
Annex
IV
Exempted application
In micro-channel plates (MCPs) used in equipment for industrial monitoring and control instruments
Expiration Date
07/21/2024
Reference
39
Restriction(s)
At least one of the following properties is present: (a) a compact size of the detector for electrons or ions, where the space for the detector is limited to a maximum of 3 mm/MCP (detector thickness + space for installation of the MCP), a maximum of 6 mm in total, and an alternative design yielding more space for the detector is scientifically and technically impracticable, (b) a two-dimensional spatial resolution for detecting electrons or ions, where at least one of the following applies: (i) a response time shorter than 25 ns, (ii) a sample detection area larger than 149 mm 2, (iii) a multiplication factor larger than 1.3 x 10^3 (c) a response time shorter than 5 ns for detecting electrons or ions, (d) a sample detection area larger than 314 mm2 for detecting electrons or ions, (e) a multiplication factor larger than 4.0 x 10^7

Help Help
Group members