Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1999
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report date:
1999

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
The boiling point could not be observed on a TA Instruments Q100 DCS using a standard heating profile. The decomposition point was measured on a TA instruments Q50 TGA. The experiment was started at 40 ºC, equilibrated for 5 min, and then the temperature was increased at 20 ºC/min to 650 ºC. The decomposition was observed as a nearly complete weight loss. The reported value of the decomposition point was determined using software supplied by TA Instruments.
GLP compliance:
not specified
Type of method:
differential thermal analysis
Remarks:
TGA

Test material

Results and discussion

Boiling point
Decomp. temp.:
> 306 °C

Any other information on results incl. tables

Decomposes before boiling

Applicant's summary and conclusion

Conclusions:
Decomposes before boiling
Executive summary:

Decomposes before boiling