Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 11 Aug 2020 to 17 Aug 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
other: ASTM D7094: “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester”
Version / remarks:
2012
Deviations:
not specified
Principles of method if other than guideline:
ASTM D7094 (modified continuously closed cup) is a commonly used and safer (low sample volume) alternative for the ISO 2719 Pensky-Martens closed cup method.
GLP compliance:
yes
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
other: Eraflash (Eralytics, Austria)
Dynamic viscosity of test material:
no data
Specific details on test material used for the study:
No boiling point up to decomposition at ca 200°C.
Key result
Atm. press.:
1 013 hPa
Remarks on result:
other: no flash point up to decomposition (at ca. 200°C).

It was visually observed that the test item reacted and/or degraded at approximately 231°C. No flammable vapour/air mixture was produced at temperatures below the temperature at which reaction and/or degradation of the test item occurred.

Interpretation of results:
other: not classified under CLP or GHS
Conclusions:
No flash-point up to decomposition (at ca. 200°C).
Executive summary:

The flash point of the substance was determined using the modified continuously closed cup ASTM D7094 method (GLP study). The substance has no flash point up to its decomposition temperature at ca. 200°C .

Description of key information

The flash point of the substance was determined using the modified continuously closed cup ASTMD7094 method (GLP study). The substance has no flash point up to its decomposition temperature at ca. 200°C

Key value for chemical safety assessment

Additional information