Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
not specified
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: MI16A047

Preliminary screening test:

The sample train can be ignited: yes

The combustion propagates along less than 100 mm: yes

The combustion propagates along more than 100 mm: no

Burning rate test must be done: no

moisture content of the sample: 0.6 %

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test substance couldn't be ignited in the preliminary test.
Executive summary:

Benzenesulfonic acid, 4-C15-16-sec-alkyl derivs.-, compd. with 1-aminopropane-2-ol was tested according EU method A10 "Flammability (solids)" 31.05.2008. The test substance couldn't be ignited in the preliminary test. No burning test had to be done. Benzenesulfonic acid, 4-C15-16-sec-alkyl derivs.-, compd. with 1-aminopropane-2-ol was judged to be "non-flammable".

Description of key information

Non flammable

Key value for chemical safety assessment

Additional information

Based on chemical structure pyrophoricity and flammability in contact with water are not expected.

Justification for classification or non-classification

No classification, the substance is a non flammable solid.

Justification: The substance is a solid which could not be ignited in a preliminary burning rate test.