Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2007-03-09 to 2007-06-12
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: GLP study performed according to EU Method A.9 (Flash-Point) and ISO 2719:2002 (Determination of flash point - Pensky-Martens closed cup method). however, the impiurities were not reported.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
yes
Remarks:
The testing facility reported the following deviations from the protocol: 1) impiurities were not reported
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
yes
Remarks:
The testing facility reported the following deviations from the protocol: 1) impiurities were not reported
GLP compliance:
yes (incl. QA statement)
Remarks:
Swiss Federal Office of Public Health
Type of method:
closed cup
Specific details on test material used for the study:
- Identity: TIC876 (T002675)
- Batch: 603T-1
- Purity: 97.76%
- Expiration date: December 19, 2007
- Storage: at room temperature (about 20°C)
Flash point:
161 °C
Atm. press.:
99 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test substance was found to be 161 deg C at 99 kPa.

Description of key information

The flash point of the substance was determined in a GLP study according to test method EC A.9 and ISO2719:2002 to be 161°C (K2, Weissenfeld, 2007). Based on the criteria as outlined in the OECD Guideline, T002675 is not a flammable substance.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
161 °C

Additional information

The flash point of T002675 was determined following the closed cup method, and using the Pensky Martens flash point tester. The flash point was tested every 2 degrees and was determined to be 161°C at 99kPa, which is above the threshold for classification for flammability (60°C).