Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27-07-2018 – 27-07-2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
ISO No., other: OECD 103
Principles of method if other than guideline:
The flash point determination of Test item Tributylmethylammonium chloride (CAS No. 56375-79-2 ) was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus.
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Name of test material : Tributylmethylammonium chloride
- Molecular formula : C13H30ClN
- Molecular weight : 235.84 g/mol
- Smiles notation : [N+](CCCC)(CCCC)(CCCC)C.[ClH-]
- InChl : 1S/C13H30N.ClH/c1-5-8-11-14(4,12-9-6-2)13-10-7-3;/h5-13H2,1-4H3;1H/q+1;/p-1
- Substance type : Organic
- Physical state : Liquid
Key result
Flash point:
191.3 °C
Atm. press.:
963.3 hPa
Remarks on result:
other: No other detail available

Method Details  Observations  Remarks if, any
 Method  Closed cup method                         

Principle of Flash point

test

The flash point of a flammable

liquid is the lowest temperature at

which there will be enough

flammable vapor to ignite when an

ignition source is applied.

 
 
 Type of method  Closed cup  
 Flash point apparatus  
  • Abel’s flash pt apparatus
  • Pensky-Martens flash point apparatus

 Pensky-Martens flash

point apparatus

Quantity of chemical

used

 g/ml

 5 ml

 Ignition source

 Gas lighter/flame

 Gas lighter

Atmospheric pressure 

 hPa

 963.3hPa

 flash pointFlash point

(RESULT)

 
°C

 191.3°C

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point determination of Test item Tributylmethylammonium chloride (CAS No. 56375-79-2 )was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus. The flash point of the test item was determine to be 191.3°C at 963.3 hPa.
Executive summary:

The flash point determination of Test item Tributylmethylammonium chloride (CAS No. 56375-79-2 )was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus. The flash point of the test item was determine to be 191.3°C at 963.3 hPa.

Description of key information

The flash point determination of Test item Tributylmethylammonium chloride (CAS No. 56375-79-2 )was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus. The flash point of the test item was determine to be 191.3°C at 963.3 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
191.3 °C

Additional information

The flash point determination of Test item Tributylmethylammonium chloride (CAS No. 56375-79-2 )was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus. The flash point of the test item was determine to be 191.3°C at 963.3 hPa.