Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27-07-2018 – 27-07-2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
ISO No., other: OECD 103
Principles of method if other than guideline:
The flash point determination of Test item Tributylmethylammonium chloride (CAS No. 56375-79-2 ) was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus.
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Name of test material : Tributylmethylammonium chloride
- Molecular formula : C13H30ClN
- Molecular weight : 235.84 g/mol
- Smiles notation : [N+](CCCC)(CCCC)(CCCC)C.[ClH-]
- InChl : 1S/C13H30N.ClH/c1-5-8-11-14(4,12-9-6-2)13-10-7-3;/h5-13H2,1-4H3;1H/q+1;/p-1
- Substance type : Organic
- Physical state : Liquid
Key result
Flash point:
191.3 °C
Atm. press.:
963.3 hPa
Remarks on result:
other: No other detail available

Method Details  Observations  Remarks if, any
 Method  Closed cup method                         

Principle of Flash point

test

The flash point of a flammable

liquid is the lowest temperature at

which there will be enough

flammable vapor to ignite when an

ignition source is applied.

 
 
 Type of method  Closed cup  
 Flash point apparatus  
  • Abel’s flash pt apparatus
  • Pensky-Martens flash point apparatus

 Pensky-Martens flash

point apparatus

Quantity of chemical

used

 g/ml

 5 ml

 Ignition source

 Gas lighter/flame

 Gas lighter

Atmospheric pressure 

 hPa

 963.3hPa

 flash pointFlash point

(RESULT)

 
°C

 191.3°C

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point determination of Test item Tributylmethylammonium chloride (CAS No. 56375-79-2 )was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus. The flash point of the test item was determine to be 191.3°C at 963.3 hPa.
Executive summary:

The flash point determination of Test item Tributylmethylammonium chloride (CAS No. 56375-79-2 )was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus. The flash point of the test item was determine to be 191.3°C at 963.3 hPa.

Description of key information

The flash point determination of Test item Tributylmethylammonium chloride (CAS No. 56375-79-2 )was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus. The flash point of the test item was determine to be 191.3°C at 963.3 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
191.3 °C

Additional information

The flash point determination of Test item Tributylmethylammonium chloride (CAS No. 56375-79-2 )was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus. The flash point of the test item was determine to be 191.3°C at 963.3 hPa.