Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-09-22 to 2016-09-23
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Type:
log Pow
Partition coefficient:
4.81
Temp.:
25 °C
pH:
7.4
Remarks on result:
other: Test item peak 1
Remarks:
overall mean, 2 replicates, 4 runs
Key result
Type:
log Pow
Partition coefficient:
5
Temp.:
25 °C
pH:
7.4
Remarks on result:
other: test item peak 2
Remarks:
overall mean, 2 replicates, 4 runs

Results obtained with the test item:

The test item showed a chromatographic profile consisting of several peaks. The peaks with retention times of 6.1 and 6.6 minutes are representing more than 93 % of the test item. The

evaluation was based on these two main peaks.

Test item peak Replicate Run Retention time (min) k' log k' log Pow Mean  Overall mean
1 1 1 6.06 3.783 0.578 4.818 4.81 4.81 ± 0.01
2 6.073 3.745 0.573 4.802
2 1 6.067 3.788 0.578 4.820 4.82
2 6.06 3.783 0.578 4.818
2 1 1 6.627 4.230 0.626 4.996 4.99 5.00 ± 0.01
2 6.64 4.188 0.622 4.979
2 1 6.633 4.235 0.627 4.997 5.00
2 6.627 4.230 0.626 4.996
Thiourea (dead time) 1 1 1.267
2 1.28
2 1 1.267
2 1.267

The R² fit of the calibration curve used was 0.993. The deviations of calculated log Pow-values from actual log Pow-values were 3 % at maximum. This reflects the linear correlation between the logarithms of the capacity factors of

the HPLC system and the log Pow-values of the reference items in the applied range of 3.0 to 6.5.

Conclusions:
The partition coefficient (n-octanol/water) of the substance was determined using the HPLC method according to OECD 117. The test item showed a chromatographic profile consisting of several peaks, the two main peaks representing more than 93% of the test item. The evaluation of the log Pow value was based on these two main peaks and were found to be 4.81 (Peak 1) and 5.00 (Peak 2).

Description of key information

The partition coefficient (n-octanol/water) of the substance was determined using the HPLC method according to OECD 117. The test item showed a chromatographic profile consisting of several peaks, the two main peaks representing more than 93% of the test item. The evaluation of the log Pow value was based on these two main peaks and were found to be 4.81 (Peak 1) and 5.00 (Peak 2).

Key value for chemical safety assessment

Log Kow (Log Pow):
5
at the temperature of:
25 °C

Additional information