Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Description of key information

The skin and eye irritation potential of 1,10 -decanediyl bismethacrylate have been evaluated based on in vitro/ex vivo studies. All the studies (OECD 439, and OECD 437) showed no skin or eye irritation.

Key value for chemical safety assessment

Skin irritation / corrosion

Link to relevant study records
Reference
Endpoint:
skin irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 May 2016 - 17 June 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: EU Method B.46 (In vitro dermal irritation)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: OECD Guideline 439 (In vitro dermal irritation)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Test system:
human skin model
Remarks:
reconstructed human epidermis
Source species:
human
Cell type:
other: human epidermal keratinocytes
Cell source:
foreskin from multiple donors
Vehicle:
unchanged (no vehicle)
Details on test system:
EpiskinTM model consists of an airlifted, living, multilayered epidermal tissue construction (surface 0.38 cm2) supplied by SkinEthic Laboratories, Lyon, France.
Control samples:
yes, concurrent negative control
yes, concurrent positive control
Amount/concentration applied:
TEST MATERIAL- Amount(s) applied (volume or weight with unit): 10 µL of the test item.NEGATIVE CONTROL- Amount(s) applied (volume or weight): 10 µLPOSITIVE CONTROL- Amount(s) applied (volume or weight): 10 µL- Concentration (if solution): SDS at 5% (w/v).
Duration of treatment / exposure:
Exposure period of 15 minutes, followed by rinsing.
Duration of post-treatment incubation (if applicable):
42-hour recovery period.
Number of replicates:
Triplicate tissues for each tested substance (test item, negative control, positive control).
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
treated
Value:
109
Vehicle controls validity:
valid
Negative controls validity:
not examined
Positive controls validity:
valid
Remarks on result:
no indication of irritation
Other effects / acceptance of results:
ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: mean cOD of the three negative controls should be = 0.6 and the Standard Deviation (SD) value of the % viability should be = 18%,
- Acceptance criteria met for positive control: relative mean viability of the positive control should be = 40% of the relative mean viability of the negative control and the SD value of the % viability should be = 18%.

All acceptance criteria for the negative and positive controls were fulfilled. The study was therefore considered to be valid.
Following a 15 minutes exposure and 42 hours of recovery period, the relative mean viability of the tissues treated with the test item was 109% with a standard deviation of 2%.
As the mean viability was > 50% after the MTT reduction, theIL-1a concentration in culture media samples retained from the three negative controls and the three test item-treated tissues were analysed by ELISA.
The IL-1a concentration value of one tissue was found Below the Limit of Quantification (< 5.00 pg/mL). Consequently, the mean IL-1a concentration from the three test item-treated tissues was not calculated. The IL-1a concentration values of the two other test item-treated tissues were found < 60 pg/mL (5.04 and 20.0 pg/mL).
Therefore, the results met the criteria for an in vitro classification as non-irritant to skin.
Interpretation of results:
GHS criteria not met
Conclusions:
Under the experimental conditions of this study, the test item 1,10-decanediyl bis methacrylate is considered to be non-irritant to skin. According to the results of this study, the classification of the test item should be:- no Category (UN GHS and Regulation (EC) No. 1272/2008).
Executive summary:

The objective of this study was to evaluate the skin irritation potential of the test item,1,10-decanediyl bis methacrylate, using the Episkin reconstructed human epidermis model.

The study design was based upon international guidelines (OECD Guideline No. 439 and Commission Regulation (EC) No. 761/2009, B.46).

 

Methods

Preliminary tests were performed to detect the ability of the test item to directly reduce MTT as well as its colouring potential.

Following the preliminary tests, the skin irritation potential of the test item was tested in the main test. The test item and both the negative and positive controls were applied topically on triplicate tissues and incubated at room temperature for 15 minutes. At the end of the treatment period, each tissue was rinsed with D-PBS and incubated for 42 hours at +37°C, 5% CO2 in a humidified incubator.

The cell viability was then assessed by means of the colourimetric MTT reduction assay.

Relative viability values were calculated for each tissue and expressed as a percentage of the mean viability of the negative control tissues which was set at 100% (reference viability).

In addition, the concentration of the inflammatory mediator IL-1a was evaluated in the culture medium retained following the 42-hour recovery period. This quantification, based on an ELISA assay, was performed since the mean relative viability of the test item-treated tissues was > 50% following the MTT reduction assay.

 

Results

 

Preliminary tests

In the preliminary tests, the test item was found not to have direct MTT reducing properties or colouring potential.

 

Main test

All acceptance criteria for the negative and positive controls were fulfilled. The study was therefore considered to be valid.

Following a 15 minutes exposure and 42 hours of recovery period, the relative mean viability of the tissues treated with the test item was 109% with a standard deviation of 2%.

As the mean viability was > 50% after the MTT reduction, the IL-1a concentration in culture media samples retained from the three negative controls and the three test item-treated tissues were analysed by ELISA.

The IL-1a concentration value of one tissue was found Below the Limit of Quantification (< 5.00 pg/mL). Consequently, the mean IL-1a concentration from the three test item-treated tissues was not calculated. The IL-1a concentration values of the two other test item-treated tissues were found < 60 pg/mL (5.04 and 20.0 pg/mL).

Therefore, the results met the criteria for an in vitro classification as non-irritant to skin.

Conclusion

Under the experimental conditions of this study, the test item 1,10-decanediyl bis methacrylate is considered to be non-irritant to skin.

Endpoint conclusion
Endpoint conclusion:
no adverse effect observed (not irritating)

Eye irritation

Link to relevant study records
Reference
Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20 May 2016 - 02 June 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: EU method B.47 (In vitro eye irritation)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: OECD guideline 437 (In vitro eye irritation)
Version / remarks:
2013
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Species:
cattle
Strain:
not specified
Details on test animals or tissues and environmental conditions:
Species: bovine cattle (Bos taurus).Origin: bovine eyes were obtained from freshly slaughtered cattle at the abattoir EVA, Saint Pierre sur Dives, France.Age: bovine cattle were up to 12 months old.Reason for choice: bovine corneas are recommended by regulatory authorities for this type of study. They are adapted for the evaluation of potential ocular irritants since they are part of the target organ.Transport from Supplier to CiToxLAB France: the eyes were transported to CiToxLAB France at ambient temperature, immerged in buffered Hanks medium containing an antibiotic [Hank’s Balanced Salts Solution (HBSS) plus penicillin/streptomycin (100 units/100 µg/mL final)]. A container with smooth internal surfaces was used for the transport to avoid damage to the corneas.Upon arrival at CiToxLAB France, the selection and preparation of corneas was performed as soon as possible. At each step of the preparation procedure, care was taken to avoid touching the corneas in order not to damage them.Selection: a careful macroscopic examination was performed on all eyes to detect the presence of any defects (opacity, scratches, pigmentation, etc). Any eyes with defects were discarded. The examination was performed under a lamp, using HBSS in order to keep the eyes moistened and shiny. Particular attention was paid to the corneas and the eyes were swiveled in order to observe the fringe areas and any scratches directly under the light.Preparation of the selected corneas: the tissues surrounding the eyeball were carefully pulled away and the cornea, surrounded by approximately 2 to 3 mm of sclera, was dissected out. The isolated corneas were stored in HBSS until all corneas had been prepared. Washing of the corneas: the corneas were washed for 15 minutes, three times, in HBSS plus penicillin/streptomycin (100 units/100 µg/mL final) at room temperature. The corneas were used within a maximum of 24 hours.Storage of the corneas: as the corneas were not used immediately, they were stored after washing. Each cornea was stored individually in 12 mL of M199 medium containing 5% dextran, plus penicillin/streptomycin, at +4°C, for a maximum of 24 hours before use. (Pre)Incubation T°C: 32°CDates of experimental phase: from 01 June 2016 to 02 June 2016
Vehicle:
unchanged (no vehicle)
Controls:
other: in vitro negative and positive controls
Amount / concentration applied:
TEST MATERIAL - Amount(s) applied (volume or weight with unit): 750 µL
Duration of treatment / exposure:
Exposure period of 10 minutes (± 30 seconds), followed by rinsing
Duration of post- treatment incubation (in vitro):
Opacity measurement:- before treatment- after 2-hour incubation in water bath at +32°C (± 1°C)Permeability measurement and macroscopic examinations:- after 90-min incubation in water, following the 2nd opacity measurement
Number of animals or in vitro replicates:
Not applicableTriplicate corneas for each tested substance (test item, negative control, positive control)
Details on study design:
REMOVAL OF TEST SUBSTANCE- Rinsing: the test substance was removed from the front opening of the anterior chamber and the epithelium was rinsed 3 times with pre-warmed medium.NEGATIVE CONTROL:As the test item was tested undiluted (i.e. in its original form), 0.9% Sodium Chloride (NaCl) was used as negative control.Since several test items were assayed concurrently, the negative control was shared.POSITIVE CONTROL: As the test item was tested using a 10-minute treatment, the positive control was Absolute ethanol. It was used neat and sampled on the day of use.Since several test items were assayed concurrently, the positive control was shared.SCORING SYSTEM/TOOL- Opacity:Using an opacitometerThe average change in opacity during exposure is determined. It is corrected by subtracting the average negative control value from values in positive control and test item.- Permeability:Using a spectrophotometer: optical density (OD) at 490 nm wavelengthThe optical density is corrected by subtracting the average negative control value from values in positive control and test item.- Scoring:In vitro irritancy score (IVIS) = Corrected Opacity + (15 x Corrected OD)Interpretation: see below
Irritation parameter:
in vitro irritation score
Run / experiment:
treated
Value:
0
Vehicle controls validity:
valid
Other effects / acceptance of results:
Macroscopic examinations : No notable opaque spots or irregularities were observed on test item-treated corneas.
 
In Vitro Irritancy Score : With one exception (mean OD490nm of the negative control), all acceptance criteria were fulfilled. The study was therefore considered as valid.

The mean In Vitro Irritancy Score (IVIS) of the test item-treated corneas was: 0.
Interpretation of results:
GHS criteria not met
Conclusions:
Under the experimental conditions of this study, the test item was identified as a test item not requiring classification for eye irritation or serious eye damage.
Executive summary:

The objective of this study was to evaluate the potential irritant and corrosive properties of the test item to the eye. The Bovine Corneal Opacity and Permeability (BCOP) test method can identify chemicals inducing serious eye damage and chemicals not requiring classification for eye irritation or serious eye damage.

The design of this study was based on the guideline OECD Guideline 437 and the study was performed in compliance with CiToxLAB France standard operating procedures and with the OECD Principles of Good Laboratory Practice.

Method

Corneas obtained from freshly slaughtered calves were mounted in corneal holders. Both chambers of the corneal holder were filled with complemented MEM culture media (cMEM) and pre-incubated for 1 hour and 5 minutes (± 5 minutes) at +32°C.

A single experiment was performed using three corneas for each treated series (test item, positive control and negative control).

Before the treatment, a first opacity measurement was performed on each cornea using an opacitometer.

The test item, applied undiluted, the negative and positive controls were evaluated in a single experiment using a treatment time of 10 minutes and the closed-chamber treatment method. At the completion of the treatment period, all items were removed from the front opening of the anterior chamber and the epithelia were rinsed.

The corneas were then incubated for 2 hours (± 10 minutes) at +32°C before a second opacity measurement was performed.

After the second opacity measurement, the medium of the anterior chamber was removed and filled with a fluorescein solution. The holders were then incubated vertically for 90 minutes (± 5 minutes) at +32°C.

At the end of the incubation period, the optical density of the solution from the posterior chamber of each holder was measured in order to determine the permeability of the cornea. Each cornea was then observed for opaque spots and other irregularities.

Results

Macroscopic examinations

No notable opaque spots or irregularities were observed on test item-treated corneas.

 

In Vitro Irritancy Score

With one exception (mean OD490nm of the negative control), all acceptance criteria were fulfilled. The study was therefore considered as valid.

The mean In Vitro Irritancy Score (IVIS) of the test item-treated corneas was: 0.

 

As the test item induced a mean IVIS < 3, the test item was considered as a test chemical not requiring classification for eye irritation or serious eye damage (UN GHS No Category).

Conclusion

Under the experimental conditions of this study, the test item was identified as a test item not requiring classification for eye irritation or serious eye damage (UN GHS No Category).

Endpoint conclusion
Endpoint conclusion:
no adverse effect observed (not irritating)

Respiratory irritation

Endpoint conclusion
Endpoint conclusion:
no study available

Additional information

In vitro skin irritation studies:

The objective of this study was to evaluate the skin irritation potential of the test item,1,10-decanediyl bis methacrylate, using the Episkin reconstructed human epidermis model. The study design was based upon international guidelines (OECD Guideline No. 439 and Commission Regulation (EC) No. 761/2009, B.46).

In the key study (Richez 2016) : the test item was found not to have direct MTT reducing properties or colouring potential.

All acceptance criteria for the negative and positive controls were fulfilled. The study was therefore considered to be valid.

Following a 15 minutes exposure and 42 hours of recovery period, the relative mean viability of the tissues treated with the test item was 109% with a standard deviation of 2%.

As the mean viability was > 50% after the MTT reduction, the IL-1a concentration in culture media samples retained from the three negative controls and the three test item-treated tissues were analysed by ELISA.

The IL-1a concentration value of one tissue was found Below the Limit of Quantification (< 5.00 pg/mL). Consequently, the mean IL-1a concentration from the three test item-treated tissues was not calculated. The IL-1a concentration values of the two other test item-treated tissues were found < 60 pg/mL (5.04 and 20.0 pg/mL).

Under the experimental conditions of this study, the test item 1,10-decanediyl bis methacrylate is considered to be non-irritant to skin.

In the supporting study (Heppenheimer, 2010), the same results were observed : after treatment with the test item, the relative absorbance values were not reduced. Therefore the test item is not considered to possess an irritant potential.

Ex vivo eye corrosion study (OECD 437, Richez 2016):

The objective of this study was to evaluate the potential irritant and corrosive properties of the test item to the eye. The Bovine Corneal Opacity and Permeability (BCOP) test method can identify chemicals inducing serious eye damage and chemicals not requiring classification for eye irritation or serious eye damage. The design of this study was based on the guideline OECD Guideline 437 and the study was performed in compliance with CiToxLAB France standard operating procedures and with the OECD Principles of Good Laboratory Practice.

Corneas obtained from freshly slaughtered calves were mounted in corneal holders. Both chambers of the corneal holder were filled with complemented MEM culture media (cMEM) and pre-incubated for 1 hour and 5 minutes (± 5 minutes) at +32°C.

A single experiment was performed using three corneas for each treated series (test item, positive control and negative control).

No notable opaque spots or irregularities were observed on test item-treated corneas.

With one exception (mean OD 490 nm of the negative control), all acceptance criteria were fulfilled. The study was therefore considered as valid.

The meanIn Vitro Irritancy Score (IVIS) of the test item-treated corneas was: 0.

As the test item induced a mean IVIS < 3, the test item was considered as a test chemical not requiring classification for eye irritation or serious eye damage.

Justification for classification or non-classification

Based on the available data, no classification is required for skin or eye irritation endpoints according to the Regulation EC. 1272/2008.