Study period:
From December 3rd to December 14th, 2016.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
flask method
Key result
Water solubility:
9.74 g/L
Conc. based on:
test mat.
Temp.:
20 °C
pH:
4
Key result
Water solubility:
0.14 g/L
Conc. based on:
test mat.
Temp.:
20 °C
pH:
7
Key result
Water solubility:
0.082 g/L
Conc. based on:
test mat.
Temp.:
20 °C
pH:
10

Table 1. Water solubility results for test substance at three pH values.

pH4

Mixing time at 30 ºC [days]

1

2

3

 

1 flask

Concentration   g/kg

9,86

9,68

9,72

 

2 flask

Concentration   g/kg

9,69

9,71

9,79

 

Average concentration of  successive days, g/kg

9,78

9,70

9,76

 

Average concentration of , g/kg

9,74

 

pH7

 

 

 

 

 

Mixing time at 30 ºC [days]

1

2

3

 

1 flask

Concentration   g/kg

0,142

0,144

0,138

 

2 flask

Concentration   g/kg

0,135

0,149

0,135

 

Average concentration of on successive days, g/kg

0,139

0,147

0,137

 

Average concentration of , g/kg

0,14

 

pH10

 

 

 

 

 

Mixing time at 30 ºC [days]

1

2

3

 

1 flask

Concentration , g/kg

0,080

0,075

0,097

 

2 flask

Concentration , g/kg

0,090

0,075

0,076

 

Average concentration of  on successive days, g/kg

0,085

0,075

0,087

 

Average concentration of , g/kg

0,08

 

 

Conclusions:
The solubility of the test item at 20 ± 0.5 ºC in buffer solutions: at pH 4.0 is 9.74 g/L; at pH 7.0 is 0.14 g/L; at pH 10.0 is 0.082 g/L.
Executive summary:

The determination of solubility of the test item in water at three pH values, using the shake flask method, was carried out according to EU method A.6 / OECD 105, under GLP conditions. The substance was dissolved in buffer solutions (pH 4.0, 7.0 and 10.0) at a temperature above the test temperature (30 ºC). When saturation was achieved, the mixture was cooled and kept at the test temperature (20 ºC). Subsequently, the mass concentration of the substance in the aqueous solution, which must not contain any undissolved particles, was determined after one, two and three days by a suitable HPLC method. The solubility of the test substance at 20 ± 0.5 ºC in buffer solutions was determined to be 9.74 g/L at pH 4.0; 0.14 g/L at pH 7.0; and 0.082 g/L at pH 10.0.

Description of key information

Key study. Method according to OECD 105 / EU Method A.6 (flask method), GLP study. The solubility of the test substance at 20 ± 0.5 ºC in buffer solutions was determined to be 9.74 g/L at pH 4.0; 0.14 g/L at pH 7.0; and 0.082 g/L at pH 10.0.

Key value for chemical safety assessment

Water solubility:
0.14 g/L
at the temperature of:
20 °C