Endpoint:
explosiveness
Type of information:
other: Expert statement
Adequacy of study:
key study
Study period:
2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
accepted calculation method
Remarks:
Expert statement
Principles of method if other than guideline:
Expert statement
GLP compliance:
no
Parameter:
other: Explosive (not specified)
Remarks on result:
negative (not further specified)
Interpretation of results:
non explosive
Remarks:
Migrated information
Conclusions:
The substance is considered to be non-explosive according to Directive 67/548/EEC and Regulation (EC) 1272/2008 and no further testing is required.
Executive summary:

In summary, analysis of the chemical structure reveals no alerts for explosive properties. The calculated chemical oxygen balance is above the trigger value of -200, but the determination of the exothermic decomposition energy demonstrated an energy release far below the critical value of 500 J/g. Therefore the substance is considered to be non-explosive according to Directive 67/548/EEC and Regulation (EC) 1272/2008 and no further testing is required.

Endpoint:
explosiveness, other
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
accepted calculation method
Remarks:
expert statement
Justification for type of information:
REPORTING FORMAT FOR THE ANALOGUE APPROACH

1. HYPOTHESIS FOR THE ANALOGUE APPROACH
This read-across is based on the hypothesis that the source and the target substance have very similar physicochemical and (eco)toxicological properties because their chemical structures are nearly identical. An analogue approach has thus been employed. The target substance is the meta-isomer of the dye Reactive Blue 049, where the sulphonate group is bound at the meta-position of the aminobenzene moiety. The source chemical is the reaction mass of both the meta-isomer and the para-isomer of Reactive Blue 049.
The presence of sulphonate groups make both dyes highly water soluble and therefore less critical for human health and environmental issues. Based on their chemical similarity, similar properties are expected in both humans and the environment.

2. SOURCE AND TARGET CHEMICAL(S)
Source: Reactive Blue 49 meta/para (CAS# 72214-18-7 / EC# 276-481-8)
Target: Reactive Blue 49 meta (CAS# 72927-99-2 / EC# 277-040-2)

3. ANALOGUE APPROACH JUSTIFICATION
see attachment under 4.2 Melting point / freezing point
Reason / purpose for cross-reference:
read-across source
Parameter:
other: Explosiveness
Remarks:
(not specified)
Remarks on result:
negative (not further specified)
Interpretation of results:
GHS criteria not met
Conclusions:
The substance is considered to be non-explosive according to Regulation (EC) 1272/2008 and no further testing is required.
Executive summary:

In summary, analysis of the chemical structure reveals no alerts for explosive properties. The calculated chemical oxygen balance is above the trigger value of -200, but the determination of the exothermic decomposition energy demonstrated an energy release far below the critical value of 500 J/g. Therefore the substance is considered to be non-explosive according to Regulation (EC) 1272/2008 and no further testing is required.

Description of key information

The substance is considered to be non-explosive.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Analysis of the chemical structure reveals no alerts for explosive properties. The calculated chemical oxygen balance is above the trigger value of -200, but the determination of the exothermic decomposition energy demonstrated an energy release far below the critical value of 500 J/g. Therefore the substance is considered to be non-explosive according to Regulation (EC) 1272/2008 and no further testing is required.

Justification for classification or non-classification

The substance is considered to be non-explosive according to Directive 67/548/EEC and Regulation (EC) 1272/2008 and no further testing is required.