Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 219-941-5 | CAS number: 2579-20-6
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- calculation (if not (Q)SAR)
- Adequacy of study:
- key study
- Study period:
- September 2010
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: Result is the output from a well-known estimation model for environmental distribution factors. The result was calculated on the basis of reliable test data (experimentally-derived log Pow).
- Qualifier:
- no guideline followed
- Principles of method if other than guideline:
- In the absence of suitable testing data, the Adsorbtion / Desorption Coefficient was estimated using a computer model, based on the structure, and information on the log Kow, boiling point, water solubility, and vapour pressure. The computer model used was EPIWeb, and the calculation of Koc was performed by KOCWIN version 2.00.
- Type:
- log Koc
- Value:
- 1.473
- Remarks on result:
- other: Value calculated using the Kow method.
- Type:
- log Koc
- Value:
- 2.71
- Remarks on result:
- other: Value calculated using the Molecular Connectivity Index (MCI) method
- Conclusions:
- The calculated log Koc, derived on the basis of the experimentally determined log Kow (log Kow = 0.78) was 1.473.
- Executive summary:
An environmental modelling program, EPIWeb, was used to estimate the Adsorbtion / Desorption coefficient. The CAS number was used to identify the substance and to recover the SMILES notation and estimate the molecular weight; a number of measured physico-chemical parameters (log Kow, Boiling point, Vapour pressure, and water solubility).
The calculated log Koc value based on the log Kow was found to be 1.473; the value calculated on the basis of the MCI (Molecular Connectivity Index) method was 2.710.
The value calculated on the basis of the log Kow method was considered slightly more reliable as it was based on an experimentally-derived value; this is the value which will be reported.
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- calculation (if not (Q)SAR)
- Adequacy of study:
- supporting study
- Study period:
- 12 November 1999 to 10 January 2000
- Reliability:
- 3 (not reliable)
- Rationale for reliability incl. deficiencies:
- other: see 'Remark'
- Remarks:
- GLP study performed in accordance to OECD test guideline, however the experimental estimation could not be performed as no suitable HPLC method could be established. A subsequent structure-based estimation gave too wide a margin for error for the result to be considered reliable.
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Deviations:
- yes
- Principles of method if other than guideline:
- Deviations: As a result of the chemical nature of 1,3-BAC, the adsorption coefficient could not be measured using the procedure specified in the OECD draft document (Dec 1998). Therefore, using a 'Molecular Topology/Fragment Contribution Method For Predicting Soil Sorption Coefficients', the log10Koc of 1,3-BAC was calculated .
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC estimation method
- Media:
- soil/sewage sludge
- Test temperature:
- HPLC system:
Column temperature: 30°C
Mobile phase: methanol:water (55:45 v/v)
pH of mobile phase: 6.0
Flow rate: 1ml/min
UV detector wavelength: 210 nm
Injection volume: 10µl
GC system:
Oven temperature program: initial 105 ºC for 1 minute, rate 16 ºC/minute, final 210 ºC for 5 minutes
Injection temperature: 250 ºC
Nitrogen-phosphorus detector temperature: 300ºC
Injection volume: 1 µl
Retention time: ca 7 mins - Details on study design: HPLC method:
- EQUIPMENT
- Apparatus: HPLC System: Hewlett-Packard 1050, incorporating autosampler and workstation
- Type, material and dimension of analytical (guard) column: Column: Nucleosil 5µ CN (250 mmx4.6 mm id)
- Detection system: GC: Hewlett-packard 5890A, incorporating autosampler and workstation
MOBILE PHASES
- Type: methanol:water (55:45 v/v)
- Experiments with additives carried out on separate columns: no
- pH: 6.0
- Solutes for dissolving test and reference substances: methanol and formamide, respectively
DETERMINATION OF DEAD TIME
- Method: by means of homologous series
REFERENCE SUBSTANCES
- Identity: formamide, acetanilide, phenol, atrazine, isoproturon, triadimenol, linuron, naphthalene, fenthion, alpha endosulfan, phenanthrene, diclofop-methyl, DDT
DETERMINATION OF RETENTION TIMES
- Quantity of test substance introduced in the column: 10 µl
- Quantity of reference substances: 10 µl
REPETITIONS
- Number of determinations: 2 for each reference stubstance
EVALUATION
- Calculation of capacity factors k': k= tr – t0 / t0
- Determination of the log Koc value: PCKOCWIN - Details on test conditions:
- Test material (0.1240g) was diluted to 50.0 ml with methanol.
- Type:
- log Koc
- Value:
- ca. 3
- Details on results (HPLC method):
- - Retention times of reference substances used for calibration:
Formamide: 3.798; acetanilide: 4.469; phenol: 4.405; atrazine:4.776; isoproturon: 5.161; triadimenol:5.442; linuron:5.854; naphthalene:6.328; fenthion:7.590; alpha endosulfan:7.458; phenanthrene:8.705; diclofop-methyl: 8.550; DDT:11.980
- Details of fitted regression line (log k' vs. log Koc): -0.999x + 0.259y=0 (r=0.966) - Transformation products:
- not measured
- Validity criteria fulfilled:
- no
- Remarks:
- Experimental determination as described in the OECD test guideline was not possible. Subsequently a computer model was used instead.
- Conclusions:
- As a result of the chemical nature of 1,3-BAC, the adsorption coefficient could not be measured. Therefore using a molecular topology/fragment contribution method for predicting soil sorption coefficients, the log10Koc of 1,3-BAC was calculated to be 3.0 +/- 1.0.
- Executive summary:
As a result of the chemical nature of 1,3-BAC, the adsorption coefficient could not be measured using the procedure specified in the OECD draft document (December 1998): Estimation of the Adsorption Coefficient (Koc) on Soil and Sewage Sludge using High Performance Liquid Chromatography (HPLC), as no suitable detection method could be found. Using a 'Molecular Topology/Fragment Contribution Method For Predicting Soil Sorption Coefficients', the log10Kocof 1,3-BAC was calculated to be 3.0 ± 1.0.
Referenceopen allclose all
Since the adsorption coefficient could not be measured using the technique specified in the study protocol, the log10Koc was estimated from the chemical structure. The chemical structure was entered directly into PCKOCWIN Version 1.66, software produced by the Syracuse Research Corportation. This software incorporates the ‘Molecular Topology/Fragment Contribution Method for Predicting Soil Sorptoin Coefficients’, W Melyan, P H Howard and R S Boethling, Environ. Sci. Technol. 26: 1560-7 (1992). The calculated value for log10Koc was 3.0. The calculation was validated and an estimate of the accuracy obtained by entering into PCKOCWIN the structures for a series of reference compounds, selected because they contain functional groups found in 1,3-BAC; the estimated accuracy was +/- 1.0 log units.
Description of key information
Log10 Koc of 1,3-BAC was estimated by calculation to be 1.473. The respective Koc value is 29.7 L/kg.
Key value for chemical safety assessment
- Koc at 20 °C:
- 29.7
Additional information
An environmental modelling program, EPIWeb, was used to estimate the Adsorbtion / Desorption coefficient. The CAS number was used to identify the substance and to recover the SMILES notation and estimate the molecular weight; a number of measured physico-chemical parameters (log10 Kow, Boiling point, Vapour pressure, and water solubility).
The calculated log10 Kocvalue based on the log10 Kowwas found to be 1.473; the value calculated on the basis of the MCI (Molecular Connectivity Index) method was 2.710.
The value calculated on the basis of the log10 Kowmethod was considered slightly more reliable as it was based on an experimentally-derived value; this is the value which will be reported.
In a study intended to measure the Koc (Safepharm, 2000), it was noted that as a result of the chemical nature of 1,3-BAC, the adsorption coefficient could not be measured using the procedure specified in the OECD draft document (December 1998): Estimation of the Adsorption Coefficient (Koc) on Soil and Sewage Sludge using High Performance Liquid Chromatography (HPLC), as no suitable detection method could be found. Using a 'Molecular Topology/Fragment Contribution Method For Predicting Soil Sorption Coefficients', the log10 Koc of 1,3-BAC was calculated to be 3.0 ± 1.0. The EPIWeb estimation was run in response to the result for the estimation in the 2000 study; it was considered that an error margin of ±1.0 was too wide for the calculated log10 Koc value to be considered reliable; on this basis, the EPIWeb result was used for calculations in environmental modelling.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.