Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The test was performed according to an industry accepted guideline.
Qualifier:
according to guideline
Guideline:
other: ASTM D445-97 Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids 9th Calculation of Dynamic Viscosity)
Deviations:
no
GLP compliance:
no
Remarks:
ISO 9001/2000 Certified
Type of method:
capillary viscometer (static)
Temp.:
other: 100.0°C
Parameter:
other: cSt
Value:
4.263
Temp.:
40°C
Parameter:
other: cSt
Value:
24.46
Conclusions:
Following the method in ASTM D445-97, the viscosity of the test substance was determined to be 4.263 cSt at 100 C and 24.46 cSt at 40 C.
Executive summary:

Following ASTM D445-97 guidelines, the viscosity of the test substance was determined to be 4.263 cSt at 100 C and 24.46 cSt at 40 C.

Description of key information

The viscosity of the substance was determined to be 24.46 cSt at 40ºC; study conducted in accordance with ASTM D445-97; Adam (2010)

Key value for chemical safety assessment

Additional information

In a non-GLP compliant viscosity study conducted in accordance with standardised guidelines, the viscosity of the test substance was determined using the capillary method. Under the conditions of the test, the viscosity of the substance was determined to be 24.46 cSt at 40ºC.