Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: OECD 104
GLP compliance:
yes (incl. QA statement)
Type of method:
dynamic method

Test material

Constituent 1
Chemical structure
Reference substance name:
Valeryl chloride
EC Number:
211-330-1
EC Name:
Valeryl chloride
Cas Number:
638-29-9
Molecular formula:
C5H9ClO
IUPAC Name:
pentanoyl chloride
Test material form:
liquid

Results and discussion

Boiling point
Key result
Boiling pt.:
128.11 °C
Atm. press.:
1 013.25 hPa
Remarks on result:
other: The normal boiling temperature was obtained by intrapolation/extrapolation from the vapour pressure curve.

Any other information on results incl. tables

Results:

Temperature
[t/°C]
Vapour Pressure
[p/hPa]
  Measurement Calculation
29.17 19.94 19.942
36.66 29.92 29.930
46.77 49.88 49.891
53.88 69.86 69.831
61.84 99.74 99.675
78.82 199.7 199.58
89.79 299.6 299.91
104.78 499.6 499.98
115.49 699.8 700.10
127.81 1005.6 1004.62

The regression cf the results leads with a mean deviation cf 0.06 % to the following equation:

In(p/hPa) = 16.5594 - 3293.69 I (213.61 + t/°C)

The test item is liquid in the temperature range used for the vapour pressure measurements.

The normal boiling temperature was obtained by extrapolation from the vapour pressure curve.

Applicant's summary and conclusion