Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
ca. 1 s
Moisture (wt %):
0
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Description of key information

Key value for chemical safety assessment

Additional information

Justification for classification or non-classification