Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
6 - 19 Dec 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: ASTM D7094. Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 002602456
- Physical state: colorless, clear liquid
- Expiration date of the lot/batch: 07 June 2020

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature
- Stability under test conditions: test substance stable in water, but extremely volatile
Key result
Remarks on result:
other: no flash point up to 61 °C (test item boiled)

No flash-point was observed below 61 °C, the temperature at which the test item boiled.

Interpretation of results:
GHS criteria not met
Conclusions:
MTDID 22327 has no flash point up to 61 °C according to ASTM D7094.
Executive summary:

The flash point of MTDID 22327 was tested using a closed-cup method. Starting at 25 °C, an attempt was made to ignite the vapour of the test substance for every 2 °C temperature rise. No flash was observed below 61 °C, at which temperature the test item boiled. The study was conducted in accordance with ASTM D7094 and was GLP compliant; therefore the study is considered reliable without restrictions.

Description of key information

MTDID 22327 has no flash point up to 61 °C according to ASTM D7094.

Key value for chemical safety assessment

Additional information

The flash point of MTDID 22327 was tested using a closed-cup method. Starting at 25 °C, an attempt was made to ignite the vapour of the test substance for every 2 °C temperature rise. No flash was observed below 61 °C, at which temperature the test item boiled. This temperature is greater than the normal boiling point but is not unexpected for a closed testing apparatus. The study was conducted in accordance with ASTM D7094 and was GLP compliant; therefore the study is considered reliable without restrictions.