First-aid measures

Emergency measure - Inhalation: Remove from source of exposure. If signs of toxicity occur

seek medical attention. Provide symptomatic/supportive care

as necessary.

Emergency measure - Eyes: Remove from source of exposure. Flush with copious amounts

of water. If irritation persists or signs of toxicity occur

seek medical attention. Provide symptomatic/supportive care

as necessary.

Emergency measure - Skin: Remove from source of exposure. Flush with copious amounts

of water. If irritation persists or signs of toxicity occur

seek medical attention. Provide symptomatic/supportive care

as necessary.

Emergency measure - Ingestion: Remove from source of exposure. If signs of toxicity occur

seek medical attention. Provide symptomatic/supportive care

as necessary.

Fire-fighting measures

Recommended extinguishing agent: Water spray, carbon dioxide, dry chemical or foam.

Product arising from burning: The substance is combustible and will burn if involved in

a fire, evolving noxious fumes (eg carbon and nitrogen

oxides and chlorine gas).

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing

apparatus must be worn.

Fight the fire from a safe distance or protected location.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.

Wear appropriate personal protective equipment conforming to

the relevant national or international standards, as

mentioned in section 2.3.10.

Absorb spillages of solutions with a suitable inert material

(eg. sand or soil). Carefully transfer the spillage to

waste containers, or use a sealed industrial vacuum machine.

Containers filled with waste material must be labelled in

the same way as the original substance containers.

Clean the spillage area with suitable cleaning materials.

Dispose of waste material in accordance with local

regulations by incineration.

Handling and storage

Handling: The substance should be stored, handled and used under

conditions of good industrial hygiene and in conformity with

any local regulations in order to avoid exposure.

Engineering controls:  In order to reduce exposure to the

substance, processing takes place in closed facilities and

local exhaust ventilation is used at the opening of the

drum.

When exposure cannot be prevented or adequately controlled

appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate

international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical protective clothing to Standard EN368

Eye protection to Standard EN166.

Furthermore, when respiratory protective equipment has to be

used, it must be capable of adequately controlling

exposure, be suitable for the purpose, and conform to the

appropriate international or national standards, such as a

dust mask conforming to EN146.  These measures should be

regarded as a minimum.

Storage: Store in a cool, dry place away from sources of ignition.

Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: BTS 58726 will be transported as a 50/50 mixture in toluene

in 200 litre epoxy-coated mild steel drums.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: Avoid crushing the containers. In the event of a spillage,
observe the warning labels on the container.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None.

Chemical reaction with water: None which is hazardous.

Dust explosion: Not applicable.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Discharge to the environment will not occur. Recovery from

minor spillages or accidental discharge is not economically

or technically feasible, and such waste material will be

disposed of by incineration. In principle, it  may be

possible to recover larger spillages of uncontaminated

material for subsequent use.

Industry - Possibility of neutralisation: The notification tests have shown that the substance is

toxic by acute and prolonged oral ingestion, systemically

harmful in contact with skin and locally irritating to skin.

It is also a severe eye irritant. No chemical treatment is

practicable to neutralise the hazardous health properties.

The substance is very toxic to aquatic organisms and may

cause long term adverse effects in the aquatic environment.

No chemical treatment is practicable to neutralise the

hazardous environmental properties.

Industry - Possibility of destruction: controlled discharge: Not possible.

Industry - Possibility of destruction - incineration: The substance should be disposed of by incineration by

burning under controlled conditions at a licensed waste

treatment   processor in accordance with local regulations.

Stack gases should be scrubbed, because noxious fumes (eg.

carbon and nitrogen oxides and chlorine gas) could be

formed.

Industry - Possibility of destruction - water purification: The substance should not be discharged directly to the

sewage system or the aqueous environment.

Industry - Possibility of destruction - other: None.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.

Public at large - Possibility of destruction - others: None.