Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009-06-17
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: According to OECD test guideline

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
GLP compliance:
no
Type of method:
capillary viscometer (static)

Test material

Constituent 1
Chemical structure
Reference substance name:
3,4,5,6,7,8,9,10,11,12,13,14-dodecahydro-2H-cyclododeca[b]pyran
EC Number:
251-090-5
EC Name:
3,4,5,6,7,8,9,10,11,12,13,14-dodecahydro-2H-cyclododeca[b]pyran
Cas Number:
32539-83-6
Molecular formula:
C15H26O1
IUPAC Name:
2H,3H,4H,5H,6H,7H,8H,9H,10H,11H,12H,13H,14H-cyclododeca[b]pyran
Details on test material:
- Name of test material (as cited in study report): Bicyclenoxyde
- Substance type: active substance
- Physical state: viscous liquid
- Isomers composition: not concerned
- Purity test date: 2009-04-21
- Lot/batch No.: R035090421
- Storage condition of test material: at 4°C in the dark

Results and discussion

Viscosity
Temp.:
other:
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 46.23
Remarks on result:
other: At ambiance temperature and with the following accuracy: +/-0.1 mm2/s

Applicant's summary and conclusion

Conclusions:
The viscosity of the test material obtained by following Method 114 of OECD Guidelines for Testing of Chemicals is 46.23 mm2/sec by performing the Capillary Method.
Executive summary:

The viscosity of the test material obtained by following Method 114 of OECD Guidelines for Testing of Chemicals is 46.23 mm2/sec by performing the Capillary Method.