Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures

If inhaled:

Remove the subject from dusty environment and let him blow his nose.

If symptoms persist, call a physician.

In case of eye contact

- In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice.

In case of skin contact

- Wash off with soap and water.

- If symptoms persist, call a physician.

If swallowed

- Drink 1 or 2 glasses of water.

- Do NOT induce vomiting.

- Consult a physician.

Fire-fighting measures

Suitable extinguishing media

- Water

- powder

- Foam

- Dry chemical

- Carbon dioxide (CO2)

Special hazards arising from the substance or mixture

- The product is not flammable.

- Not explosive

- In case of fire hazardous decomposition products may be produced such as: Gaseous hydrogen fluoride (HF),Fluorophosgene

Advice for firefighters

- Wear self-contained breathing apparatus and protective suit.

- When intervention in close proximity wear acid resistant over suit.

- Evacuate personnel to safe areas.

- Approach from upwind.

- Protect intervention team with a water spray as they approach the fire.

- Keep containers and surroundings cool with water spray.

- Keep product and empty container away from heat and sources of ignition.

Accidental release measures

1- Personal precautions, protective equipment and emergency procedures

Advice for non-emergency personnel :

- Prevent further leakage or spillage if safe to do so.

Advice for emergency responders

- Ensure adequate ventilation.

- Avoid dust formation.

- Material can create slippery conditions.

- Sweep up to prevent slipping hazard.

- Keep away from open flames, hot surfaces and sources of ignition.

2. Environmental precautions

- Should not be released into the environment.

- Do not flush into surface water or sanitary sewer system.

3. Methods and materials for containment and cleaning up

- Sweep up or vacuum up spillage and collect in suitable container for disposal.

Handling and storage

Precautions for safe handling

- Ensure adequate ventilation.

- Avoid dust formation.

- Use personal protective equipment.

- Do not contaminate tobacco products.

- Keep away from heat and sources of ignition.

- To avoid thermal decomposition, do not overheat.

- Take measures to prevent the build up of electrostatic charge.

- Clean and dry piping circuits and equipment before any operations.

- Ensure all equipment is electrically grounded before beginning transfer operations.

Conditions for storage, including incompatibilities

     -Keep in properly labelled containers.

    - Keep away from heat and sources of ignition.

     - Keep away from combustible material.

     - Keep away from Incompatible products.

     - Provide tight electrical equipment well protected against corrosion.

Packaging material/ Suitable material

   - glass

   - Plastic material

   - Polyethylene

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN 3077
Shippingopen allclose all
Labels:
9 - Miscellaneous substances
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
UN 3077
Shippingopen allclose all
Labels:
9 - Miscellaneous substances
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
UN 3077
Shipping information
Proper shipping name and description:
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, SOLID,
N.O.S.(REACTION MASS OF BISPHENOL AND BISPHENATE
PHOSPHONIUM SALT)
Labels:
9 - Miscellaneous substances
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

§ Appropriate engineering controls

- Ensure adequate ventilation.

- Refer to protective measures listed in sections 7 and 8.

- Apply technical measures to comply with the occupational exposure limits.

§ Individual protection measures

*Respiratory protection

- In case of insufficient ventilation, wear suitable respiratory equipment.

- Respirator with a dust filter

- Recommended Filter type: P2

- In case of decomposition (see section 10), use an air breathing apparatus with face mask.

- Use only respiratory protection that conforms to international/ national standards.

§ Hand protection

- Wear protective gloves.

- Suitable material: Nitrile rubber, Neoprene gloves

- Take note of the information given by the producer concerning permeability and break through times, and of

special workplace conditions (mechanical strain, duration of contact).

§ Eye protection

- Tightly fitting safety goggles

§ Skin and body protection

- Wear work overall and safety shoes.

§ Hygiene measures

- Ensure that eyewash stations and safety showers are close to the workstation location.

- When using, do not eat, drink or smoke.

- Wash hands before breaks and at the end of workday.

- Handle in accordance with good industrial hygiene and safety practice.

§ Environmental exposure controls

- Dispose of rinse water in accordance with local and national regulations.

Stability and reactivity

Reactivity :No dangerous reaction known under conditions of normal use.

Chemical stability :Stable under recommended storage conditions.

Possibility of hazardous reactions :No dangerous reaction known under conditions of normal use.

Conditions to avoid

- To avoid thermal decomposition, do not overheat.

- Keep away from flames and sparks.

Incompatible materials

- Bases, alkaline hydroxides, Metals

Hazardous decomposition products

- Gaseous hydrogen fluoride (HF)., Fluorophosgene, Carbon oxides

Disposal considerations

Waste treatment methods

- Can be incinerated, when in compliance with local regulations.

- The incinerator must be equipped with a system for the neutralisation or recovery of HF.

- Dispose of in accordance with local regulations.

Contaminated packaging

- Empty containers can be landfilled, when in accordance with the local regulations.