First-aid measures

Description of first aid measures:

General advice: Move away from the danger area. Remove contaminated clothing immediately and store it in a safe place

If inhaled: Bring the victim to the open air. Have the victim blow his/her nose. Consult a doctor immediately.

In case of skin contact: Rinse immediately with plenty of water for at least 15 minutes. Consult a doctor immediately.

In case of eye contact: Rinse immediately with plenty of water, keeping the eyelids open, for at least 15 minutes. Consult a doctor immediately.

If swallowed       : Do not induce vomiting. Rinse mouth with water. Consult a doctor immediately.

Most important symptoms and effects, both acute and delayed:

Symptoms: Burns, Irritations.

In all cases alert a physician immediately

Indication of any immediate medical attention and special treatment needed:

Treatment : For a specific treatment, call the emergency telephone numbers indicated in the safety datasheet

Fire-fighting measures

Extinguishing media:

Suitable extinguishing media: Compatible with all common extinguishing media.

Unsuitable extinguishing media: Strong water jets.

Special hazards arising from the substance or mixture:

In case of fire, the product may emit toxic and/or irritating fumes.

Supposed thermal decomposition/oxidation:

Carbon monoxide and carbon dioxide

Nitrogen oxides (NOx)

Advice for firefighters:

Special protective equipment for firefighters: Use self-contained breathing apparatus.

Further information: Prohibit the disposal of water, used as an extinguishing medium, in the environment. Use extinguishing systems compatible with the local situation and the surrounding environment.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:

Personnel not belonging to the emergency team :

Move away immediately from the event location.

Use personal protective clothing. (see section: Exposure controls: Personal protection - Industrial scale)

Personnel belonging to the emergency team:

Remove people from the place of accidental release

Isolate the area and prohibit entry to personnel not belonging to the emergency team.

Ventilate confined spaces before entering.

Use personal protective clothing. (see section: Exposure controls: Personal protection - Industrial scale)

Use a self-contained breathing apparatus

Environmental precautions:

Do not let it enter into sewer.

Do not disperse the spilled product in the soil or in surface water

Methods and materials for containment and cleaning up:

General information:

Spray spilled water to prevent dust formation.

Collect the substance with antistatic pallets and pour into hermetically sealed PVC containers.

Send containers to disposal. Close and label thoroughly

Thoroughly clean contaminated objects and floors, in compliance with current legislation.

Collect the water used for washing with absorbent cloths for cleaning and send to the waste.

Cleaning the contaminated area: Wash the contaminated area with plenty of water.

Disposal of recovered materials: See disposal considerations

Further recommendations:

In dangerous conditions immediately evacuate the area and request the intervention of the emergency team

Handling and storage

Precautions for safe handling:

Indications for safe use (industrial scale):

Work in a defined area with access restricted to only personnel. Avoid formation and deposit of powders.

A closed transfer system is strongly recommended.

Avoid the accumulation of electrostatic charges.

Necessary equipotential connection of the plants and equipment.

In the use of chemical products, observe the normal rules of prevention of work.

Indications for safe use (laboratory scale):

Handle in a chemical hood with filter.

It is recommended to work in a defined area with limited access.

Conditions for safe storage, including any incompatibilities:

Requirements for storage rooms and containers:

Contain the substance in labeled PVC containers.

Keep in a well-ventilated area away from heat

Indications for storage together with other products:       

Do not store with strong oxidizers.

Do not store with acids.

Further information on storage conditions:       

Store in a tightly closed container in PVC, protected from moisture and light.

Storage temperature:       

Keep in a cold place (+2°C to +8°C / 36°F to 46°F)

Recommended packaging material:       

PVC.

Sensitivity

Humidity: Hygroscopic.

Light: The product is sensitive to light.

Heat: The product is sensitive to heat.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
3259
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
3259
Shipping information
Proper shipping name and description:
AMINES, SOLID, CORROSIVE, N.O.S. (1-amino-4-cyclopentylpiperazine)
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
3259
Shipping information
Proper shipping name and description:
AMINES, SOLID, CORROSIVE, N.O.S. (1-amino-4-cyclopentylpiperazine)
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Personal protection :

General protection measures:

Intermediate to be used under strictly controlled conditions

Corrosive compound: avoid all contact with skin and eyes.

Do not breath the dust.

Personal protective equipment or collective protection devices must be chosen according to the workplace, concentration and amount of hazardous material handled.

Use of suction and ventilation systems in areas in production and laboratory analysis environments.

Clarify the chemical resistance of the protective means with the supplier of the protective means.

Verify exposure to the substance by performing environmental and personal sampling.

Industrial Scale :

Respiratory protection : Wear full face mask compliant to:EN 136 class 3 + combined respiratory filter  EN14387 A2 B2 E2 K1 Hg – P3 R D

Hand protection :

Wear protective gloves

material of which the gloves are made: nitrile

layer thickness: > 0.4 mm.

Permeation time: > 480 min

conforming to:

EN 374

EN1149

Eye protection :See respiratory protection

Skin protection:                     

Protective clothing Cat. III

Protection against liquid chemicals

EN14605:2005 – (TYPE 4)

EN13982-1:2004/A1 2010 – (TYPE 5)

EN13034:2005+A12009 – (TYPE 6)

EN1149-52008 (antistatic)

Foot protection - safety footwear:

EN ISO 20345 (S3).

Other indications for the technical systems : The technical systems must be designed to ensure compliance with conditions subject to strict control.

Hygiene measures:

Do not eat, drink or smoke during work.

Wash hands thoroughly after work.

A shower is recommended

Laboratory

Respiratory protection: handle the product under a chemical hood

Hand protection:

Nitrile rubber gloves

Layer thickness: > 0.1 mm.

Penetration time: > 480 min

EN 374

EN 1149

Eye protection:

Wear protective eyewear in accordance with:

EN 166

Lens marking:

2C-1.2 – xxxx -  1 FT  CE

Frame marking:

xxxx - EN 166-FT CE

General marking of lenses + frame:

2C-1.2-xxxx-1 FT  EN 166-FT CE

(where xxxx indicates the manufacturer)

Skin Protection:

Use dedicated work clothing:

work coat to knee height, conforming to: EN13034:2009 – (TYPE 6)

Foot protection - safety footwear:

EN ISO 20345 (S3):

Hygiene measures: Wash hands before breaks and at the end of the working day.

Stability and reactivity

Safety remarks: Dust may be explosive (no data available).

Reactivity: No data available

Chemical stability:

Decomposes upon contact with air.

Decomposes on heating.

Possibility of hazardous reactions: No data available

Conditions to avoid: Exposure to moisture Exposure to air. Exposure to light. Avoid strong heating.

Incompatible materials: Strong oxidizing agents. Acids

Hazardous decomposition products: Supposed thermal decomposition/oxidation: Carbon monoxide and carbon dioxide Nitrogen oxides (NOx)

Disposal considerations

Waste treatment methods:

Product: In compliance with current legislation, send to an authorized landfill. Characterize the waste before giving it to an authorized waste disposal company.

Uncleaned packaging: The non-washable packaging must be disposed of in the same way as the contained substance. Characterize the waste before giving it to an authorized waste disposal company.