Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove the person to fresh air. Give oxygen or artificial
respiration if needed.

Seek medical attention.
Emergency measure - Eyes: Flush eyes immediately with plenty of water for 15 minutes.

Seek medical attention.
Emergency measure - Skin: Flush skin immediately with plenty of water for 15 minutes.

Seek medical attention.

Wash soiled clothing before wearing again.
Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Carbon dioxide, dry chemical, alcohol and universal foam,
and water spray.

Product arising from burning: May generate oxides of nitrogen and sulphur, and carbon
dioxide,

Product determined by test: N

Protective equipment: Fire fighters should wear air supplied respirators.

Accidental release measures

Emergency measures in case of spillage: Eliminate all ignition sources. Sweep up into containers and
seal. Dispose of material in accordance with government
requirements and ensure conformity to local disposal
regulations.

Do not wash into sewer or waterways.

Handling and storage

Handling: The preparation containing the substance will only be used
in the IC industry by trained personnel. Exposure is
minimal. Inhalation and skin contact are avoided by the use
of impermeable protective gloves and dust masks. Dust proof
filling apparatus and appropriate ventilation are also used.

Storage: The preparation containing the substance should be kept in
securely closed unbreakable containers. Keep away from
foodstuffs and sources of ignition. Store in a cool and dark
place away from humidity.

Packaging of the substance and or preparation: The preparation is packaged into either one gallon or one
quart bottle, which is then put in a cardboard box.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: The preparation containing the substance should be kept in
an appropriate, tightly closed container during transport.
Containers should be stored upright and secured against
falling down. Containers should be suitably labelled and
sealed.

Do not expose to any UV light source.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None known.

Chemical reaction with water: None known.

Dust explosion: Not anticipated.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: The preparation is not recovered or recycled during normal
use.

Any spilled material is not recovered but is disposed of by
incineration or disposal to landfill in accordance with
local regulations.

Industry - Possibility of neutralisation: Not known.

Industry - Possibility of destruction: controlled discharge: Contaminated containers or spillages of the preparation
mixed with inert material (e.g. sand or soil) may be
disposed of at an authorised tip in accordance with local
regulations.

Industry - Possibility of destruction - incineration: Incineration is the preferred method of disposal. The
preparation may be disposed of by burning under controlled
conditions at a licensed waste treatment processor in
accordance with local regulations. Stack gases should be
scrubbed as noxious fumes (e.g. carbon dioxide) could be
formed.

Industry - Possibility of destruction - water purification: In the unlikely event that the preparation should enter the
water treatment systems, contaminated waste water should be
treated by means of flocculation precipitation. The
precipitated material should then be incinerated.

Industry - Possibility of destruction - other: None known.

Public at large - Possibility of recovery/recycling: Not applicable as the test substance will not enter the
public domain.