Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 18 February 2016 to 3 March 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Analytical purity: 92%
- Expiration date of the lot/batch: 13.10.2017


Key result
Flash point:
ca. 97.5 °C
Atm. press.:
ca. 100.5 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The test substance has a flash point of 97.5ºC.
Executive summary:

The flash point of the test substance was determined in accordance with the EU Method A.9 with GLP. The method used was the closed cup with the Pensky-Martens apparatus. The test substance has a flash point of 97.5ºC.

Description of key information

Key study: Klimisch 1. According to EU Method A9. GLP study. The test substances has a flash point of 97.5ºC.   
    
    
    

The test substance has a flash point of 97.5ºC.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
97.5 °C

Additional information