Administrative data

Endpoint:
relative self-ignition temperature (solids)
Study period:
2010
Reliability:
1 (reliable without restriction)
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
Resin acids and Rosin acids, fumarated, esters with pentaerythritol
EC Number:
305-514-1
EC Name:
Resin acids and Rosin acids, fumarated, esters with pentaerythritol
Cas Number:
94581-15-4
IUPAC Name:
94581-15-4
Details on test material:
Test Substance Name: Resin acids and rosin acids, fumarated, reaction product with pentaerythritol
CAS No. 94581-15-4
Batch No. 0910002486
Supplied By Arizona Chemicals
Description: Pale yellow solid.

Results and discussion

Relative self-ignition temperature (solids)
Remarks on result:
other: The following relative self-ignition temperature (A16) result was obtained: Exempt under Annex VII

Any other information on results incl. tables

The sample was found to have an initial melting point of approximately 86.4°C during EC Physico/Chemical test A1, Melting Temperature (capillary method) (see section 7 above). Therefore, relative self ignition temperature testing is not required.

Applicant's summary and conclusion

Conclusions:
The following relative self-ignition temperature (A16) result was obtained: Exempt under Annex VII.