Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
5 October 2017 - 9 November 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Version / remarks:
March 04, 2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
DIN 51794 (Testing of mineral oil hydrocarbons - Determination of ignition temperature)
Version / remarks:
May 2003
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No. of test material: 1704HH0700/0
- Expiration date of the lot/batch: 29th April 2018
- Purity test date: Not indicated

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Room temperature
- Stability under test conditions: No specific conditions required
Auto-ignition temperature:
300 °C
Atm. press.:
>= 1 016 - <= 1 021 hPa

Table 1 Auto-ignition Temperature of the Test Item

Test

Volume


[μL]

Auto-ignition
temperature

[°C]

Ignition delay



[s]

Colour of the flame

Minimum auto-ignition
temperature
[°C]

1

70

310

9

orange/blue

304

100

304

14

150

313

11

2

60

318

10

orange/blue

304

120

309

13

200

304

12

400

313

10

3

50

321

8

orange/blue

302

250

302

18

450

315

11

Conclusions:
In conclusion the test item is auto-ignitable with an auto-ignition temperature of 300°C.
Executive summary:

Reingruber (2017) is a GLP-compliant study following EU method A.15 and is considered to be reliable without restrictions (Klimisch 1). The test item is auto-ignitable with an auto-ignition temperature of 300°C.

Description of key information

In conclusion the test item is auto-ignitable with an auto-ignition temperature of 300°C.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
300 °C

Additional information

Reingruber (2017) is a GLP-compliant study following EU method A.15 and is considered to be reliable without restrictions (Klimisch 1). The test item is auto-ignitable with an auto-ignition temperature of 300°C.