Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2006-09-27 to 2007-04-18
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study performed according to OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions) without deviations.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes (incl. QA statement)
Remarks:
Department of Health of the Government of the United Kingdom
Type of distribution:
other: sieve analysis

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): VRT-126016
- Molecular formula (if other than submission substance): not applicable
- Molecular weight (if other than submission substance): not applicable
- Smiles notation (if other than submission substance): not applicable
- InChl (if other than submission substance): not applicable
- Structural formula attached as image file (if other than submission substance): not applicable
- Substance type: no data
- Physical state: white to off-white powder
- Analytical purity: 99.8 area% by High Performance Liquid Chromatography (HPLC)
- Impurities: chloride: <0.1%
- Composition of test material, percentage of components: no data
- Isomers composition: no data
- Purity test date: 2006-02-02
- Lot/batch No.: 25719
- Expiration date of the lot/batch: February 2008
- Stability under test conditions: no data
- Storage condition of test material: at room temperature
- Other: no data

Results and discussion

Particle size
Percentile:
D50
Mean:
> 125 - <= 400 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
> 400 µm
Distribution:
43.9 %
No.:
#2
Size:
> 125 - <= 400 µm
Distribution:
51.9 %
No.:
#3
Size:
> 75 - <= 125 µm
Distribution:
3.6 %
No.:
#4
Size:
> 30 - <= 75 µm
Distribution:
0.7 %
No.:
#5
Size:
> 10 - <= 30
Distribution:
0.1 %

Any other information on results incl. tables

Not applicable

Applicant's summary and conclusion

Conclusions:
The results indicated that 0.6% by mass of the substance was smaller than 75 mircometers.
Executive summary:

Not applicable