Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2006-09-27 to 2007-04-18
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study performed according to OECD Guideline 115 (Surface Tension of Aqueous Solutions) and EU Method A.5 (Surface Tension) without deviations.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
Deviations:
no
Remarks:
: The testing facility indicated that there were no deviations from the protocol.
Qualifier:
according to guideline
Guideline:
EU Method A.5 (Surface Tension)
Deviations:
no
Remarks:
: The testing facility indicated that there were no deviations from the protocol.
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes (incl. QA statement)
Remarks:
: Certificate issued by the United Kingdom GLP monitoring authorities.
Type of method:
OECD harmonised ring method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): VRT-126016
- Molecular formula (if other than submission substance): not applicable
- Molecular weight (if other than submission substance): not applicable
- Smiles notation (if other than submission substance): not applicable
- InChl (if other than submission substance): not applicable
- Structural formula attached as image file (if other than submission substance): not applicable
- Substance type: no data
- Physical state: white to off-white powder
- Analytical purity: 99.8 area% by High Performance Liquid Chromatography (HPLC)
- Impurities: chloride: <0.1%
- Composition of test material, percentage of components: no data
- Isomers composition: no data
- Purity test date: 2006-02-02
- Lot/batch No.: 25719
- Expiration date of the lot/batch: February 2008
- Stability under test conditions: no data
- Storage condition of test material: at room temperature
- Other: no data

Results and discussion

Surface tension
Surface tension:
65.5 mN/m
Temp.:
20 °C
Conc.:
90 other: % saturation (approx. 135 mg/L)

Any other information on results incl. tables

The Harkins-Jordan corrected value was calculated to be 64.0 mN/m.

Applicant's summary and conclusion

Conclusions:
The surface tension of a 90% saturated aqueous solution of the test substance was found to be 64.0 mN/m. As the result is greater than 60 mN/m, the test substance was not considered to be surface active.
Executive summary:

Not applicable