Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Qualifier:
according to guideline
Guideline:
ASTM D3278 (Standard test methods for flash point of liquids by small scale closed-cup apparatus)
Qualifier:
according to guideline
Guideline:
ISO No., other:
Type of method:
equilibrium method closed cup

Test material

Constituent 1
Test material form:
liquid: viscous

Results and discussion

Flash pointopen allclose all
Flash point:
125 °C
Atm. press.:
102.01 kPa
Key result
Flash point:
ca. 125 °C
Atm. press.:
101.325 kPa

Applicant's summary and conclusion