ippc-ann-7-organic-solvents-dir-2010-75

IPPC, Annex VII - Technical provisions relating to organic solvents

EU. Emission Limit Values: Annex VII (installations & activities using organic solvents), Directive 2010/75/EU on Industrial Emissions (IPPC), 17 December 2010

This list contains emission limit values for polluting substances assigned according to installations and activities using organic solvents (Annex VII) under Directive 2010/75/EU on Industrial Emissions (Integrated Pollution Prevention and Control - IPPC).

Volatile organic compounds

EC / List no: - CAS no: -
Ref No.
17
Process/equipment
Manufacture of coating mixture, varnishes, inks and adhesives
Emission medium
Total emissions (the sum of fugitive emissions and emissions in waste gases)
Maximum limit
5 %
Qualifier
New installations
Solvent Consumption
> 100
Solvent Threshold
> 1000
Special provisions
Total emission limit value is expressed in % of solvent input

The fugitive emission limit value does not include solvent sold as part of a coatings mixture in a sealed container

Part
2 Thresholds and emission limit values
Notes
00 'Volatile organic compound' means any organic compound as well as the fraction of creosote, having at 293,15 K a vapour pressure of 0,01 kPa or more, or having a corresponding volatility under the particular conditions of use

01 'Fugitive emissions' means any emissions not in waste gases of volatile organic compounds into air, soil and water as well as solvents contained in any products, unless otherwise stated in Part 2 of Annex VII

06 For 'Reduction scheme', 'Emission monitoring', 'Solvent management plan' and 'Assessment of compliance with emission limit values in waste gases' see Annex VII, Parts 5, 6, 7 and 8 (Directive 2010/75/EU)

07 According to Art. 58, Chapter V 'Special provisions for installations and activities using organic solvents' (DIR 2010/75/EU): Substances or mixtures which, because of their content of volatile organic compounds classified as carcinogens, mutagens, or toxic to reproduction under Regulation (EC) No 1272/2008, are assigned or need to carry the hazard statements H340, H350, H350i, H360D or H360F, shall be replaced if possible by less harmful substances or mixtures within the shortest possible time