Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

4.1 Description of first aid measures
General advice
: Move out of dangerous area.
Show this safety data sheet to the doctor in attendance.
Do not leave the victim unattended.

If inhaled
: Call a physician or poison control centre immediately.
Move to fresh air.
If unconscious, place in recovery position and get medical attention immediately.

In case of skin contact
: If on skin, rinse well with water.
If on clothes, remove clothes.

In case of eye contact
: Remove contact lenses.
Flush eyes with water as a precaution.
Protect unharmed eye.
Keep eye wide open while rinsing.
If eye irritation persists, consult a specialist.

If swallowed
: Keep respiratory tract clear.
Do not give milk or alcoholic beverages.
Never give anything by mouth to an unconscious person.
If symptoms persist, call a physician.

4.2 Most important symptoms and effects, both acute and delayed
Symptoms :
Skin contact may provoke the following symptoms:
Allergic reactions
Inhalation may provoke the following symptoms:
Shortness of breath
Asthma
Ingestion may provoke the following symptoms:
Stomach/intestinal disorders

4.3 Indication of any immediate medical attention and special treatment needed

Fire-fighting measures

5.1 Extinguishing media
Suitable extinguishing media
: Use extinguishing measures that are appropriate to local cir-cumstances and the surrounding environment.

Unsuitable extinguishing media
: High volume water jet

5.2 Special hazards arising from the substance or mixture
Hazardous combustion products
: No hazardous combustion products are known

5.3 Advice for firefighters
Special protective equipment for firefighters
: No special protective equipment required.

Further information
: Standard procedure for chemical fires.
Use extinguishing measures that are appropriate to local cir-cumstances and the surrounding environment.

Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures
Personal precautions
:
Use personal protective equipment.
Ensure adequate ventilation.
Evacuate personnel to safe areas.

6.2 Environmental precautions
Environmental precautions
: Prevent product from entering drains.
Prevent further leakage or spillage if safe to do so.
If the product contaminates rivers and lakes or drains inform respective authorities.

6.3 Methods and material for containment and cleaning up
Methods for cleaning up
: Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).

Handling and storage

7.1 Precautions for safe handling
Advice on safe handling
: Avoid formation of aerosol.
Do not breathe vapours/dust.
Avoid exposure - obtain special instructions before use.
Avoid contact with skin and eyes.
For personal protection see section 8.
Smoking, eating and drinking should be prohibited in the ap-plication area.
Provide sufficient air exchange and/or exhaust in work rooms.
Persons susceptible to skin sensitisation problems or asth-ma, allergies, chronic or recurrent respiratory disease should not be employed in any process in which this mixture is being used.

Advice on protection against fire and explosion
: Normal measures for preventive fire protection.

Hygiene measures
: General industrial hygiene practice. Wash hands before breaks and immediately after handling the product.

7.2 Conditions for safe storage, including any incompatibilities
Requirements for storage areas and containers
: Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully re-sealed and kept upright to prevent leakage. Electrical installa-tions / working materials must comply with the technological safety standards. To maintain product quality, do not store in heat or direct sunlight.

Advice on common storage
: No materials to be especially mentioned.

Further information on stor-age stability
: Keep in a dry place. No decomposition if stored and applied as directed.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

8.1 Control parameters
Contains no substances with occupational exposure limit values.
8.2 Exposure controls
Engineering measures
Handle only in a place equipped with local exhaust (or other appropriate exhaust).
Personal protective equipment
Eye protection
: Safety glasses with side-shields conforming to EN166

Skin and body protection
: Impervious clothing
Footwear protecting against chemicals

Respiratory protection : In the case of vapour formation use a respirator with an ap-proved filter.
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators.

Stability and reactivity

10.1 Reactivity
No dangerous reaction known under conditions of normal use.
10.2 Chemical stability
No decomposition if stored and applied as directed.
10.3 Possibility of hazardous reactions
Hazardous reactions
: Stable under recommended storage conditions.

10.4 Conditions to avoid
Conditions to avoid
: Extremes of temperature and direct sunlight.

10.5 Incompatible materials
Materials to avoid
: None known.

Disposal considerations

13.1 Waste treatment methods
Product : Dispose of in accordance with the European Directives on waste and hazardous waste.
According to the European Waste Catalogue, Waste Codes are not product specific, but application specific.
Waste codes should be assigned by the user, preferably in discussion with the waste disposal authorities.

Do not dispose of waste into sewer.
Do not contaminate ponds, waterways or ditches with chemi-cal or used container.
Send to a licensed waste management company.
Dispose of as hazardous waste in compliance with local and national regulations.

Contaminated packaging : Empty remaining contents.
Dispose of as unused product.
Do not re-use empty containers.