Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
07 Apr - 11 May 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance wtih national standard methods under GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
Qualifier:
equivalent or similar to guideline
Guideline:
other: DIN Guide 51794
Deviations:
no
Qualifier:
equivalent or similar to guideline
Guideline:
other: IEC standard 79-4: "Electrical Apparatus for Explosive Gas Atmospheres, Part 4, Method of Test for Ignition Temperature"
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
procrylat
IUPAC Name:
procrylat
Details on test material:
- Name of test material (as cited in study report): MTDID 9115
- Physical state: Clear colourless to yellowish liquid
- Analytical purity: 96%
- Expiration date of the lot/batch: 24 November 2015
- Storage condition of test material: at room temperature

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
445 °C
Atm. press.:
1 027.4 - 1 031.9 hPa
Remarks on result:
other:

Applicant's summary and conclusion

Conclusions:
Procrylat has an auto-flammability temperature of 445 °C at 1027.4 - 1031.9 hPa according to EU Method A.15.
Executive summary:

Procrylat was tested using an auto-ignition temperature apparatus. The study was conducted in accordance with EU Method A.15 and was GLP compliant; therefore the study is considered reliable without restrictions.