Hydrolysis

On the basis of the experimental studies of the structurally and functionally similar read across chemical and applying the weight of evidence approach, the hydrolysis half-life value of the test chemical can be expected to be > 1 yr, at pH range 4, 7 & 9 and at a temperature of 25°C or 50°C, respectively. Thus, based on this half-life value, it can be concluded that the test chemical is not hydrolysable in water.

Additional information

Hydrolysis

Data available for the structurally and functionally similar read across chemicals has been reviewed to determine the half-life of the test chemical.The studies are as mentioned below:

The half-life of the test chemical was determined at different pH range. The study was performed according to OECD Guideline 111 (Hydrolysis as a Function of pH) at a temperature of 25°C and pH of 4, 7 and 9, respectively. The half-life value of test chemical was determined to be > 1 yr at pH 4, 7 and 9, respectively at a temperature of 25⁰C. Thus, based on this, test chemical is considered to be not hydrolysable.

In an another study, the half-life of the test chemical was determined at different pH range.The preliminary study was performed according to OECD Guideline 111 (Hydrolysis as a Function of pH) at a temperature of 50°C. Initial test chemical conc. used for the study was 20 mg/l. Analytical method involve the use of HPLC. Although the half-life value of test chemical was not known, but at the preliminary test,the residues of the test chemical were more than 90 % in all the pH. Thus, the test chemical was reported to be stable in water at a temperature of 50⁰C and at pH 4, 7 and 9, respectively. Based on the half-life values, it is concluded that the test chemical is not hydrolysable.

On the basis of the experimental studies of the structurally and functionally similar read across chemical and applying the weight of evidence approach, the hydrolysis half-life value of the test chemical can be expected to be > 1 yr, at pH range 4, 7 & 9 and at a temperature of 25°C or 50°C, respectively. Thus, based on this half-life value, it can be concluded that the test chemical is not hydrolysable in water.