Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18 February 2009 - 27 April 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Date of GLP inspection: 19/08/2008 Date of Signature on GLP certificate: 04/03/2009

Test material

Constituent 1
Details on test material:
Sponsor's identification : Eldew APS-307
Description : Pale yellow waxy solid block
Batch number : 809114
Date received : 22 December 2008
Storage conditions : room temperature in the dark
Stability under test conditions: The test material stable under the conditions used in the determination.

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
ca. 384 °C
Atm. press.:
>= 102.57 - <= 103.04 kPa
Remarks on result:
other:

Any other information on results incl. tables

Results:

Test Temperature (ºC)

Test Weight (g)

Ignition Delay (s)

Observations

50 (clean flask)

0.2

>300

No ignition.

100 (clean flask)

0.2

>300

No ignition.

150

0.2

>300

No ignition.

200

0.2

>300

No ignition.

250

0.2

>300

No ignition, grey fumes emitted.

300

0.2

 >300

 No ignition, grey fumes emitted.

350

0.2

 >300

 No ignition, grey fumes emitted.

 400 (clean flask)

0.2

 >300

 No ignition, grey fumes emitted.

 400 (clean flask)

0.4

11

An orange flame, grey fumes emitted.

 390 (clean flask)

0.4

10

 An orange flame, grey fumes emitted.

 380 (clean flask)

0.4

>300

No ignition, grey fumes emitted.

386 (clean flask)

0.4

13

 An orange flame, grey fumes emitted.

382 (clean flask)

0.4

 >300

No ignition, grey fumes emitted.

384 (clean flask)

0.4

12

 An orange flame, grey fumes emitted.

382 (clean flask)

0.6

 >300

 No ignition, grey fumes emitted.

382 (clean flask)

0.8

 >300

 No ignition, grey fumes emitted.

382 (clean flask)

1.0

>300

No ignition, grey fumes emitted.

382 (clean flask)

1.2

>300

No ignition, grey fumes emitted.

Room temperature:      19.0 °C

Applicant's summary and conclusion

Conclusions:

The test material has been determined to have an auto-ignition temperature of 384 ± 5°C.
Executive summary:
Method: The auto-ignition temperature was determined by heating aliquots of the test material in a flask and observing for any signs of ignition. Testing was conducted using Method A15 Auto- Ignition Temperature (Liquids and Gases) of Council Regulation (EC) No 440/2008 of 30 May 2008. Conclusion: The test material has been determined to have an auto-ignition temperature of 384 ± 5°C.