Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02.11.2018-27.02.2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Version / remarks:
(EC) No. 440/2008
Deviations:
not applicable
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Deviations:
no
GLP compliance:
no
Type of method:
differential scanning calorimetry
Key result
Boiling pt.:
> 400 °C
Atm. press.:
ca. 1 013.25 hPa
Decomposition:
no

DSC Measurement

Ident No. Test item / mg Starting temperature / °C Final test temperature / °C Temperature range (endothermal) / °C Crucible Observation after the measurement
38320 12.24 25 500 no sharp endothermal effects Aluminium with a hole Test item was an orange to brown solidified melt, mass loss: aprox. 1%
38324 11.9 25 500 no sharp endothermal effects Aluminium with a hole Test item was an orange to brown solidified melt, mass loss: aprox. 1%
Ident No. Test item / mg Starting temperature / °C Final test temperature / °C Temperature range (endothermal) / °C Crucible Observation after the measurement
38320 12.24 25 500 no sharp endothermal effects Aluminium with a hole Test item was an orange to brown solidified melt, mass loss: aprox. 1%
38324 11.9 25 500 no sharp endothermal effects Aluminium with a hole Test item was an orange to brown solidified melt, mass loss: aprox. 1%

The test item had no boiling point up to 400 °C under atmospheric conditions.

Conclusions:
The test item had no boiling point up to 400 °C under atmospheric conditions.
Executive summary:

A study was conducted according to OECD test guideline 103 and Regulation (EC) No 440/2008 method A.2 to determine the boiling point of the test item using differential scanning calorimetry.

The boiling point / boiling range was determined by differential scanning calorimetry (DSC). The test item and the reference are heated up from the starting temperature to the final temperature at a constant heating rate in a defined atmosphere (nitrogen). Open crucibles are used as containers for the test item and as empty reference crucible. The quantity of heat absorbed or released is measured and recorded. The test item had no boiling point up to 400 °C under atmospheric conditions.

Description of key information

The test item had no boiling point up to 400 °C under atmospheric conditions.

Key value for chemical safety assessment

Additional information

A study was conducted according to OECD test guideline 103 and Regulation (EC) No 440/2008 method A.2 to determine the boiling point of the test item using differential scanning calorimetry.

The boiling point / boiling range was determined by differential scanning calorimetry (DSC). The test item and the reference are heated up from the starting temperature to the final temperature at a constant heating rate in a defined atmosphere (nitrogen). Open crucibles are used as containers for the test item and as empty reference crucible. The quantity of heat absorbed or released is measured and recorded. The test item had no boiling point up to 400 °C under atmospheric conditions.