Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 22-24, 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 170
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
mass based distribution

Test material

Constituent 1
Test material form:
solid: flakes
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Mitsubishi-Kagaku Foods Corporation, 63281211
- Expiration date of the lot/batch: March 27, 2018
- Purity test date: October 14, 2016


STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: 1-10 degrees C in the dark

Results and discussion

Particle sizeopen allclose all
Key result
Percentile:
D10
Mean:
7 100 µm
St. dev.:
0
Remarks on result:
other: No standard deviation given
Key result
Percentile:
D90
Mean:
25 000 µm
St. dev.:
0
Remarks on result:
other: No standard deviation given
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
>= 25 000 µm
Distribution:
0 %
No.:
#2
Size:
>= 16 000 - < 25 000 µm
Distribution:
>= 20.46 - <= 31.21 %
No.:
#3
Size:
>= 10 000 - < 16 000 µm
Distribution:
>= 51.37 - <= 54.29 %
No.:
#4
Size:
>= 7 100 - < 10 000 µm
Distribution:
>= 13.65 - <= 19.31 %
No.:
#5
Size:
>= 5 000 - < 7 100 µm
Distribution:
>= 1.76 - <= 3.71 %
No.:
#6
Size:
>= 4 000 - < 5 000 µm
Distribution:
>= 0.09 - <= 0.29 %
No.:
#7
Size:
>= 3 350 - < 4 000 µm
Distribution:
>= 0.15 - <= 0.27 %
No.:
#8
Size:
>= 2 000 - < 3 350 µm
Distribution:
>= 0.34 - <= 0.36 %
No.:
#9
Size:
>= 1 000 - < 2 000 µm
Distribution:
>= 0.28 - <= 0.31 %
No.:
#10
Size:
>= 500 - < 1 000 µm
Distribution:
>= 0.28 - <= 0.32 %

Any other information on results incl. tables

0.02 g of material was in the pan at the end of the experiment. The tap density was determined to be 0.48 g/mL.

Applicant's summary and conclusion

Conclusions:
90% of the test substance LMDT had a particle size greater than 7100 microns.
Executive summary:

The particle size of LMDT was determined using the sieve method. The test was performed in duplicate. 90% of the test substance LMDT had a particle size greater than 7100 microns.