Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental phase started 16th June 2016 and completed on the 15th January 2017.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method

Test material

Constituent 1
Chemical structure
Reference substance name:
Ethylidynetrimethanol
EC Number:
201-063-9
EC Name:
Ethylidynetrimethanol
Cas Number:
77-85-0
Molecular formula:
C5H12O3
IUPAC Name:
2-(hydroxymethyl)-2-methylpropane-1,3-diol
Test material form:
solid: granular

Results and discussion

Density
Key result
Type:
relative density
Density:
ca. 1 220 kg/m³
Temp.:
20.3 °C

Any other information on results incl. tables

Results

Calibration

The pressure readings and the calculated volume for the reference and sample cells are shown in the following table:

Table 6

Determination

P1
(psig)

P2
(psig)

P3
(psig)

P4
(psig)

Reference cell volume (cm3)

Sample cell volume (cm3)

1

17.313

6.557

17.367

8.610

90.740

148.848

2

17.049

6.459

16.951

8.403

90.885

149.012

3

17.150

6.501

17.278

8.564

91.145

149.300

Mean reference cell volume :          90.953 cm3
Mean sample cell volume     :          149.225 cm3

As the reference cell volume and sample cell volume were within the defined tolerance (90.953 ± 1.0 cm3and 149.225 ± 1.0 cm3for the reference and sample cell volumes respectively) the gas comparison pycnometer was therefore considered acceptable for u

 Sample

The pressure readings, calculated volumes and density values obtained for the test item are shown in the following table:

Table 7

Determination

Test

P1(sample)
(psig)

P2(sample)

(psig)

Volume (cm3)

Density

(kg/m3)

Mean density (kg/m3)

1

A

17.120

7.615

35.564

1.222 x 103

1.22 x 103

B

17.050

7.581

35.487

1.225 x 103

C

17.073

7.589

35.427

1.227 x 103

2

A

17.113

7.557

34.079

1.221 x 103

1.22 x 103

B

17.112

7.555

34.037

1.222 x 103

C

17.049

7.523

33.922

1.226 x 103

Mean density             :          1.22 x 103 kg/m3
Relative density         :          1.22
Temperature              :          20.3 ± 0.5 °C

 Discussion

Duplicate determinations were performed to ensure a reproducibility of less than ± 20 kg/m3was obtained.

Applicant's summary and conclusion

Conclusions:
The density of the test item has been determined to be 1.22 x 103 kg/m3 at 20.3 ± 0.5 °C (relative density: 1.22).