Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
1995
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry

Test material

Constituent 1
Chemical structure
Reference substance name:
Benzyltris(dimethylaminato)phosphorus(1+) chloride
EC Number:
253-141-7
EC Name:
Benzyltris(dimethylaminato)phosphorus(1+) chloride
Cas Number:
36636-04-1
Molecular formula:
C13H25ClN3P
IUPAC Name:
benzyl-tris(dimethylamino)phosphanium chloride
impurity 1
Chemical structure
Reference substance name:
Water
EC Number:
231-791-2
EC Name:
Water
Cas Number:
7732-18-5
Molecular formula:
H2O
IUPAC Name:
water
impurity 2
Reference substance name:
Sum of other impurities
IUPAC Name:
Sum of other impurities
Test material form:
solid: particulate/powder

Results and discussion

Melting / freezing point
Key result
Melting / freezing pt.:
172.5 °C
Atm. press.:
1 013 hPa
Decomposition:
no
Sublimation:
no

Applicant's summary and conclusion

Conclusions:
The test item Tecnoflon Stufe 2 has a melting point of 172.5 °C at atmospheric pressure (1013 hPa) as determined by differential scanning calorimetry according to Regulation EC No. 440/2008 Method A.1., OECD Test Guideline 102 (1995), EPA OCSPP 830.7200 (1998) and CIPAC MT 1 (2009).