Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Data is from study report
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Principles of method if other than guideline:
Measurement of resistance to flow using Redwood Viscometer No. 1.

GLP compliance:
no
Type of method:
other: Redwood Viscometer No. 1
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
22.02
Remarks on result:
other: Dynamic viscosity
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
19.96
Remarks on result:
other: Dynamic viscosity

Calculation of Dynamic Viscosities:

 

ν= ct----------------------------------------- (i)

Where, ν= Kinematic viscosity

c= Viscometer constant

t= time of flow in seconds (Redwood second) For Redwood Viscometer- I, the values for the constants are as

below:

Time of flow, t

C

40 to 85 seconds

0.264

85 to 2000

0.247

ν= η/ρ------------------------------ (ii)

Where, ν= Kinematic viscosity

η= Dynamic viscosity

ρ= Density of fluid

1. Calculation of Kinematic Viscosities:

For Test Temperature at 20°C

ν=ct

= 79 × 0.264sec

= 20.85mm²/sec

For Test Temperature at 40°C

ν=ct

= 71.6 × 0.264sec

= 18.90 mm²/sec

2. Calculation of Dynamic Viscosities:

For Test Temperature at 20°C

ν= η/ρ

Page 2 of 4 UERL/PC/007-02

20.85 =η 1.056

η = 20.85 x 1.056

= 22.02 mPa.S

For Test Temperature at 40°C

ν= η/ρ

18.90 =η/ 1.056

η = 18.90 x 1.056

= 19.96 mPa.S              

Conclusions:
Dynamic viscosity (calculated) of test chemical at 20 degree C and 100 degree C is 22.02 mPa.S and 19.96 mPa.S, respectively.
Executive summary:

The viscosity determination of test substance was done as per the test guideline OECD 114 using Redwood Viscometer No. 1. Dynamic viscosity (calculated) of test chemical at 20°C and 40°C is 22.02mPa.S and 19.96mPa.S, respectively.

Description of key information

Dynamic viscosity (calculated) of test chemical at 20°C and 40°C is 22.02mPa.S and 19.96mPa.S, respectively.

Key value for chemical safety assessment

Viscosity:
22.02 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

The viscosity determination of test substance was done as per the test guideline OECD 114 using Redwood Viscometer No. 1. Dynamic viscosity (calculated) of test chemical at 20°C and 40°C is 22.02mPa.S and 19.96mPa.S, respectively.