Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
06/01/2009 to 09/03/2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP in accordance with recognised guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Results and discussion

Relative self-ignition temperature (solids)
Relative self-ignition temperature:
> 400 °C
Remarks on result:
other:

Any other information on results incl. tables

The cube contained black charred remains.

Applicant's summary and conclusion

Conclusions:
The test material has been determined not to have a relative self-ignition temperature below 400°C.
Executive summary:

In a determination of hazardous physico-chemical properties study (Harlan project number: 0959/0225) the test material

has been determined not to have a relative self-ignition temperature below 400°C.

The test material was heated in an oven and the relative self ignition temperature determined. Testing was conducted using Method A16 Relative Self-IgnitionTemperature for Solids of Council Regulation (EC) No 440/2008 of 30 May 2008, Part A:Methods for the determination of physico-chemical properties.