First-aid measures

General advice : For an immediate medical attention, call a doctor/physician to request a medicinal emergency aid.

If inhaled : Remove to fresh air and keep patient at rest in a position comfortable for breathing.

In case of skin contact : Take off contaminated clothing and wash it before reuse. If on skin, wash with plenty of water.

In case of eye contact : Flush with water while holding eyelids open for at least 15 minutes.

If swallowed : Never give anything by mouth to an unconscious person. Wash out mouth with water. Do not induce vomiting unless directed by medical personnel.

Treat the patient on the basis of his symptoms. Use of personal protective equipments is recommended to the person in charge of the immediate medical attention.

Fire-fighting measures

Suitable extinguishing media : Water spray, CO2, dry chemical, chemical foam.

Unsuitable extinguishing media : No data available.

Formation of toxic gases (CO, CO2) is possible during heating or fire.

During all fire fighting activities, wear appropriate personal protective equipments (Self-contained breathing apparatus (SCBA)). Cool exposed containers.

Extinguish flames at a safe distance from the containers, by using fire hoses or extinguishers automatic systems with nozzles positioned at the top of the containers.

Remove the containers from the fire area or keep containers cool. Damaged containers must be handled only by authorized trained personnel.

Accidental release measures

Evacuate from affected area the personnel not involved in emergency intervention. Alert internal emergency personnel or fire-fighters.

If immediate action is necessary refer to the instructions / directions for emergency personnel.

Wear appropriate protective clothing and equipment consistent with the degree of hazard.

If applicable, stop spillage or leakage and eliminate all sources of ignition.

Stop leakage to the outside (sewers…).

Contain the wide-spreading product thanks to non combustible absorbent materials (sand…) and collect it in a drum for destruction or treatment. During containment and cleaning up operations, insure adequate ventilation.

Wash the soil with water and detergent.

Handling and storage

Avoid release to the environment. Handle the substance according to the good manufacturing practices.

Technical measures : Keep the container hermetically sealed.

Storage conditions : Store in a cool, dry and well-ventilated area.

Incompatible materials : Strong oxidizers.

Packaging compatibilities : No data available.

Packaging materials : Valethene drums.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Individual protection : Gloves, glasses, respiratory protective equipment, protective work clothing. Personal protective equipments have to be adapted to the risk assessment and European (EN) and International (ISO) standards.

Occupational hygiene practices : Provide adequate ventilation in work place relating to the operation. After handling, remove carefully personal protective equipment and wash with plenty of water before storing or destruction for disposable overall.

Environmental exposure controls : Environmental monitoring by appropriate devices is in place.

For more information contact the supplier.

Stability and reactivity

Stable under normal pressure and temperature conditions of use. Thermally stable up to the boiling point ~ 260°C.

Keep away from excessive heat, flames and other ignition sources.

Strong oxidizing agents.

Toxic fumes (CO, CO2)

Disposal considerations

Incineration. Dispose of in manner consistent with federal, state, and local regulations. Packaging waste : avoid dispersion of the product and send to an waste management center for destruction in accordance with the state regulation.